ONE DIMENTIONAL HEAT FLUX DISTRIBUTION CHARACTERS IN LOWER FURNACE OF BOILERS WITH WET BOTTOM
|更新时间:2025-09-28
|
ONE DIMENTIONAL HEAT FLUX DISTRIBUTION CHARACTERS IN LOWER FURNACE OF BOILERS WITH WET BOTTOM
Thermal Power GenerationVol. 39, Issue 9, Pages: 27-29(2010)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK221
Published:2010
稿件说明:
移动端阅览
YAN Xianglin, XU Dangqi, NIE Jianping Xi'an Thermal Power Research Institute Co Ltd. ONE DIMENTIONAL HEAT FLUX DISTRIBUTION CHARACTERS IN LOWER FURNACE OF BOILERS WITH WET BOTTOM[J]. Thermal power generation, 2010, 39(9): 27-29.
DOI:
YAN Xianglin, XU Dangqi, NIE Jianping Xi'an Thermal Power Research Institute Co Ltd. ONE DIMENTIONAL HEAT FLUX DISTRIBUTION CHARACTERS IN LOWER FURNACE OF BOILERS WITH WET BOTTOM[J]. Thermal power generation, 2010, 39(9): 27-29.DOI:
ONE DIMENTIONAL HEAT FLUX DISTRIBUTION CHARACTERS IN LOWER FURNACE OF BOILERS WITH WET BOTTOM
摘要
以某1025t/h液态排渣锅炉为研究对象
对其下炉膛一维热流密度分布情况进行了计算
所得计算结果与下炉膛各段水冷壁吸热量吻合较好。计算表明
烟气温度、热流密度以及水冷壁的吸热热流密度的变化规律基本一致
随着煤粉颗粒的燃烧、热量的释放
烟气温度、热流密度以及水冷壁的吸热热流密度逐渐增加
但到达峰值后又呈下降趋势。
Abstract
Taking a 1 025 t/h boiler with wet bottom as an object to be studied
the one-dimentional heat flux density distribution situation in the lower furnace has been calculated
the result obtained from calculation tallies better with the absorbed heat of water-wall in each section of the lower furnace.The calculation shows that the regularity of variation for flue gas temperature
for heat flux density
as well as for heat flux density of water-wall absorbed heat are basically identical.Along with burning of pulverized coal particles and releasing of heat
the flue gas temperature
the heat flux density
and the heat flux density of water-wall absorbed heat are gradually increased
but the decreasing tendency appeared again after reaching the peak value