RETROFIT OF PRE-TREATMENT SYSTEM IN SHANGDU POWER PLANT
|更新时间:2025-09-28
|
RETROFIT OF PRE-TREATMENT SYSTEM IN SHANGDU POWER PLANT
Thermal Power GenerationVol. 39, Issue 6, Pages: 62-64(2010)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2010
稿件说明:
移动端阅览
ZHU Xuebing, MAO Jin, ZHANG Jiangtao, et al. RETROFIT OF PRE-TREATMENT SYSTEM IN SHANGDU POWER PLANT[J]. Thermal power generation, 2010, 39(6): 62-64.
DOI:
ZHU Xuebing, MAO Jin, ZHANG Jiangtao, et al. RETROFIT OF PRE-TREATMENT SYSTEM IN SHANGDU POWER PLANT[J]. Thermal power generation, 2010, 39(6): 62-64.DOI:
RETROFIT OF PRE-TREATMENT SYSTEM IN SHANGDU POWER PLANT
The quality of effluent water from original pretreatment system in shangdu power plant can't satisfy the requirements stipulated in design from begining to end
leading to serious blockage in disc-type filter and on the ultra filtration membrane.Combining with the characters of intake water quality
i.e.low temperature and low turbidity
a retrofit scheme of the pre-treatment system has been put forward and implemented;(1)additionally installing inclined pipes in the clarifying pond with mechanical agitation;(2)adding dosing points of coagulant aids;(3)adding multi-medium filters after the said clarifying pond.After retrofitling
the results of test in operation show that the quality of effluent water from said clarifying pond and from the multi-medium fiter is good