Thermal Power GenerationVol. 40, Issue 3, Pages: 55-57(2011)
作者机构:
华能大连电厂
作者简介:
基金信息:
DOI:
CLC:TK223.34
Published:2011
稿件说明:
移动端阅览
GAO Deshun, GONG Jiahong Huaneng Dalian Power Plant. RETROFIT MEASURES OF THE ROTARY AIR PREHEATERS[J]. Thermal power generation, 2011, 40(3): 55-57.
DOI:
GAO Deshun, GONG Jiahong Huaneng Dalian Power Plant. RETROFIT MEASURES OF THE ROTARY AIR PREHEATERS[J]. Thermal power generation, 2011, 40(3): 55-57.DOI:
RETROFIT MEASURES OF THE ROTARY AIR PREHEATERS
摘要
针对回转式空气预热器(空预器)普遍存在的漏风大、冷端易腐蚀和堵灰等问题
采取了双密封技术、固定密封技术
以及利用固定式水洗装置进行在线水冲洗
检修时采用高压水射流清洗
空预器冷端受热面选用COR-TEN钢、搪瓷和陶瓷材料等耐腐蚀材料等措施
实施后上述问题得以解决。
Abstract
Directing against the problems existing commonly in rotary air preheaters
such as large air leakage
as well as corrosion and ash-clog occurred easily on the cold end etc.
analysis has been carried out
and retrofit measures being put forward
including adoptation of double-seal and fixed seal technologies
using fixed water flushing facility to realize on-line water flushing
and using high-presurre water to carried out jet cleaning during repair
and the cold end of air preheater has to use corrosion resistant materials
such as COR-TEN steel
enamel and ceramic materials etc..After implementation
the above-mentioned problems all have been resolved.