您当前的位置:
首页 >
文章列表页 >
ELIMINATION OF LOW-FREQUENCY VIBRATION TROUBLE ON THE BEARING OF GENERATOR NO.1 IN TIANWAN NUCLEAR POWER PLANT
更新时间:2025-09-28
    • ELIMINATION OF LOW-FREQUENCY VIBRATION TROUBLE ON THE BEARING OF GENERATOR NO.1 IN TIANWAN NUCLEAR POWER PLANT

    • Thermal Power Generation   Vol. 39, Issue 12, Pages: 92-95(2010)
    • CLC: TK263.64
    • Published:2010

    移动端阅览

  • HUANG Qian, ZHANG Fuhai, ZHANG Yong, et al. ELIMINATION OF LOW-FREQUENCY VIBRATION TROUBLE ON THE BEARING OF GENERATOR NO.1 IN TIANWAN NUCLEAR POWER PLANT[J]. Thermal power generation, 2010, 39(12): 92-95. DOI:

  •  
  •  

0

Views

145

下载量

4

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

ANALYSIS OF STEAM FLOW EXCITED VIBRATION ON STEAM TURBINE NO 3 IN ZHANJIANG POWER PLANT AND TREATMENT THEREOF
ENERGYSAVING AND CAPACITYINCREASING RETROFIT OF STEAM TURBINE FOR 100 MW UNIT IN HUAYINSHAN POWER PLANT
ANALYSIS AND REMEDY FOR VIBRATION OCCURRED ON 330 MW TURBO-GENERATOR SETS MADE BY ROMANIA
ANALYSIS OF SHAFT NO.2 VABRITION FOR UNIT NO.1 IN MEIZHOUWAN POWER PLANT AND DISPOSAL THEREOF
COMPREHENSIVE REPORT OF ANALYSIZING VIBRATION CHARACTERS FOR SUPERCRITICAL 600 MW UNITS

Related Author

ZHENG Zhanyou
ZHU Yun
LI Jian
DANG Yuan-jian
GUO Ping-ying
LIU Min21.Huadian Meizhouwan Power Plant
CHEN Ke-zhen1
WANG Xin-jie21.Xi'an Thermal Power Research Insitute Co Ltd

Related Institution

Zhanjiang Power Plant
Guodian Huayingshan Power Plant
Northwest Electric Power Test and Research Institute
Northwest Electric Power Construction Debugging and Construction Research Institute
Huadian Meizhou Bay Power Plant
0