ANALYSIS OF LVDT FAILURE FOR GOVENOR VALVE OF STEAM TURBINE EQUIPPED FOR SUBCRITICAL 600 MW UNIT AND RETROFIT THEREOF
Thermal Power GenerationVol. 40, Issue 1, Pages: 79-81(2011)
作者机构:
国华锦界能源有限责任公司
作者简介:
基金信息:
DOI:
CLC:TK267
Published:2011
稿件说明:
移动端阅览
ZHU Ke, GAO Shenghui, ZHANG Fuzhong, et al. ANALYSIS OF LVDT FAILURE FOR GOVENOR VALVE OF STEAM TURBINE EQUIPPED FOR SUBCRITICAL 600 MW UNIT AND RETROFIT THEREOF[J]. Thermal power generation, 2011, 40(1): 79-81.
DOI:
ZHU Ke, GAO Shenghui, ZHANG Fuzhong, et al. ANALYSIS OF LVDT FAILURE FOR GOVENOR VALVE OF STEAM TURBINE EQUIPPED FOR SUBCRITICAL 600 MW UNIT AND RETROFIT THEREOF[J]. Thermal power generation, 2011, 40(1): 79-81.DOI:
ANALYSIS OF LVDT FAILURE FOR GOVENOR VALVE OF STEAM TURBINE EQUIPPED FOR SUBCRITICAL 600 MW UNIT AND RETROFIT THEREOF
摘要
在分析汽轮机调节阀线性可变差动变送器(LVDT)常见故障的基础上
提出了调节阀阀杆区域加装防转装置和万向节装置
调整LVDT同心度
增设调节阀行程偏差大报警逻辑等改进措施
并以此对国华锦界电厂亚临界600 MW机组汽轮机调节阀LVDT进行了改进。经过1年的试运行
改进后的调节阀未再发生LVDT反馈杆与套筒摩擦和LVDT反馈杆变形的现象
LVDT各部件受力均匀
阀位反馈测量准确
调节阀反馈定位精度和连续运行可靠性显著提高。
Abstract
On the basis of analysing common failures occurred on the linear variable differential transducers(LVDT) of steam turbines
some retrofit measures
i.e.adding rotation-preventing device in the valve stem region of the govenor valve
adding universal coupling facility
adjusting the concentricity of LVDT
adding alarm logic for large deviation of govenor valve's stroke
etc.
have been put forward
and the LVDT of govenor valve for steam turbine of subcritical 600 MW unit in Guohua Jinjie Power Plant being retrofitted according to the said measures.After retrofitting
the phenomena occurred on the govenor valve
such as friction between feedback stem of LVDT and the sleeve
deformation of feedback stem in LVDT etc.
have never occurred again in trial operation of one year.All parts of LVDT are stressed uniformly
the feedback of valve position being accurately measured
the setting precision of govenor valve's feedback and the reliability in continous operation have been remarkabally enhanced.
ANALYSIS OF ABNORMAL AXIAL DISPLACEMENT IN STEAM TURBINE OF 600 MW UNIT MADE BY ALSTOM CORPORATION AND HANDLING THEREOF
STUDY ON AND COUNTERMEASURES FOR ERRORS APPEARED IN MEASUREMENT OF DIFFERENTIAL EXPANSION IN LOW-PRESSRUE CYLINDER FOR 600 MW STEAM TURBINE MANUFACTURED BY ALSTOM
APPLICATION OF LOAD-PREESTIMATING SIGNAL IN THE COORDINATED CONTROL SYSTEM OF UNITS
Selection of steam-driven induced draft fan considering piping thermal efficiency
Simulation study on coordinated control system of subcritical 600 MW unit
Related Author
XIE Cheng
ZHOU Yi-zheGuodian Beilun Power Generation Co Ltd no.1
RONG Zhao-yang
HAN Ji-wen Guodian Beilun Power Plant
LI Chengming
SONG Zhiqiang
CHENG Junjun Huaneng Tongchuan Power Plant
JIN Rong
Related Institution
Guodian Beilun First Power Generation Co., Ltd
Guodian Zhejiang Beilun Power Plant
Huaneng Tongchuan Power Plant
School of Energy and Environmental Engineering, Shanghai Electric Power University
School of Mechanical and Power Engineering, Shanghai Jiao Tong University