STUDY ON THE ON-LINE PERFORMANCE CALCULATION OF THERMAL POWER UNITS BASED ON SYMPHONY SYSTEM AND REALIZATION THEREOF
|更新时间:2025-09-28
|
STUDY ON THE ON-LINE PERFORMANCE CALCULATION OF THERMAL POWER UNITS BASED ON SYMPHONY SYSTEM AND REALIZATION THEREOF
Thermal Power GenerationVol. 40, Issue 5, Pages: 39-41(2011)
作者机构:
武汉大学动力与机械学院
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2011
稿件说明:
移动端阅览
LUO Kun, FANG Yuan, FANG Yanjun College of Power and Mechanical Engineering. STUDY ON THE ON-LINE PERFORMANCE CALCULATION OF THERMAL POWER UNITS BASED ON SYMPHONY SYSTEM AND REALIZATION THEREOF[J]. Thermal power generation, 2011, 40(5): 39-41.
DOI:
LUO Kun, FANG Yuan, FANG Yanjun College of Power and Mechanical Engineering. STUDY ON THE ON-LINE PERFORMANCE CALCULATION OF THERMAL POWER UNITS BASED ON SYMPHONY SYSTEM AND REALIZATION THEREOF[J]. Thermal power generation, 2011, 40(5): 39-41.DOI:
STUDY ON THE ON-LINE PERFORMANCE CALCULATION OF THERMAL POWER UNITS BASED ON SYMPHONY SYSTEM AND REALIZATION THEREOF
An on-line energy consumption calculation method for thermal power units has been put forward on the basis of symphony system from ABB Corporation in USA.Taking BRC 300 as the operational controller
the runing parameters of units are obtained on-line from the DCS
to compile the C language programm
and being embedded in Symphony DCS;by using the equivalent enthalpy reduction method and anti-balance method
the running situation of units has been analysed
and the energy consumption characteristics of units being calculated and obtained.The results of calculation are compared with the practical results of thermal tests
the relative error of specific heat consuption is 0.5%
and the relative error of boiler efficiency is 0.42%
it shows the feasibility of this on-line calculation method.