DIFFERENT TECHNICAL MEASURES FOR REDUCING HEAT LOSS OF FLUE GAS FROM COAL-FIRED BOILERS AND SELECTION PRINCIPLE THEREOF
|更新时间:2025-09-28
|
DIFFERENT TECHNICAL MEASURES FOR REDUCING HEAT LOSS OF FLUE GAS FROM COAL-FIRED BOILERS AND SELECTION PRINCIPLE THEREOF
Thermal Power GenerationVol. 40, Issue 7, Pages: 15-18(2011)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK229.6
Published:2011
稿件说明:
移动端阅览
WANG Chunchang Xi'an Thermal Power Research Institute Co Ltd. DIFFERENT TECHNICAL MEASURES FOR REDUCING HEAT LOSS OF FLUE GAS FROM COAL-FIRED BOILERS AND SELECTION PRINCIPLE THEREOF[J]. Thermal power generation, 2011, 40(7): 15-18.
DOI:
WANG Chunchang Xi'an Thermal Power Research Institute Co Ltd. DIFFERENT TECHNICAL MEASURES FOR REDUCING HEAT LOSS OF FLUE GAS FROM COAL-FIRED BOILERS AND SELECTION PRINCIPLE THEREOF[J]. Thermal power generation, 2011, 40(7): 15-18.DOI:
DIFFERENT TECHNICAL MEASURES FOR REDUCING HEAT LOSS OF FLUE GAS FROM COAL-FIRED BOILERS AND SELECTION PRINCIPLE THEREOF
Different kinds of main technologies for reducing the heat loss of flue gas exhausted from coal-fired boilers and the features of them have been briefly presented
and based on this
an approach to their matching behavior
with operating conditions of boilers as well as the basic principle for selecting technical kinds being emphatically made.The main conclusions are listed as in the following:(1) The non-balancing control technique of inlet flue gas flow rate into the air preheater
as well as the rotation-inversing measure for rotor in the air preheater should be popularized on large-capacity boilers as a common technology;(2) in creasing the surface area of air preheater should be considered as a firstly selecting technology for reducing heat loss of flue gas exhausted from the boilers
and the next is increasing the surface area of economizer;(3) under specific conditions
the low-pressure economizer technology can play a role in energy-saving
in the event of increasing surface area of the econoizer being feasible
a techno-economic comparison between them has to be carried out;(4) the heater technology of hot primary air is only suitable to the coal-pulverizing sytsem with large amount of cold air to bemixed.
CAUSE ANALYSIS OF HIGH EXHAUST GAS TEMPERATURE FROM HG-450/13.7-YM24 BOILER AND RETROFIT THEREOF
ANALYSIS OF PLATE-TURNOVER PHENOMENON CONCERNING RUDUCTION GEARBOX OF 29-VI(T) 1780 TYPE AIR PREHEATER SURPASSING THE CLUTCH COUPLING AND TECHNICAL RETROFITTING OF THE STARTING-UP CIRCUIT
ANALYSIS AND TREATMENT OF SOMEWHAT LOWER MAIN STEAM TEMPERATURE PROBLEM FOR 2045 t/h BOILER
INFLUENCE OF SCR DENITRIFICATION FACILITY UPON THE BOILER STRUCTURE
ESTABLISHMENT OF SERVICE LIFE MANAGEMENT SYSTEM FOR HIGH-TEMPERATURE BOILER TUBES IN THERMAL POWER PLANT BASED ON B/S STRUCTURE