FAULT DIAGNOSIS AND DISPOSAL OF VIBRATION ON 1036 MW UNIT NO.2 IN HUANENG HAIMEN POWER PLANT
|更新时间:2025-09-28
|
FAULT DIAGNOSIS AND DISPOSAL OF VIBRATION ON 1036 MW UNIT NO.2 IN HUANENG HAIMEN POWER PLANT
Thermal Power GenerationVol. 40, Issue 7, Pages: 62-66(2011)
作者机构:
1. 西安热工研究院有限公司
2. 华能海门电厂
作者简介:
基金信息:
DOI:
CLC:TM621.3
Published:2011
稿件说明:
移动端阅览
WANG Yanbo1, ZHANG Weijiang2 1.Xi'an Thermal Power Research Institute Co Ltd. FAULT DIAGNOSIS AND DISPOSAL OF VIBRATION ON 1036 MW UNIT NO.2 IN HUANENG HAIMEN POWER PLANT[J]. Thermal power generation, 2011, 40(7): 62-66.
DOI:
WANG Yanbo1, ZHANG Weijiang2 1.Xi'an Thermal Power Research Institute Co Ltd. FAULT DIAGNOSIS AND DISPOSAL OF VIBRATION ON 1036 MW UNIT NO.2 IN HUANENG HAIMEN POWER PLANT[J]. Thermal power generation, 2011, 40(7): 62-66.DOI:
FAULT DIAGNOSIS AND DISPOSAL OF VIBRATION ON 1036 MW UNIT NO.2 IN HUANENG HAIMEN POWER PLANT
In trial operation of 1036 MW unit no2 in Huaneng Haimen Power Plant
the oil film whirling
impact-rubbing between movable and stationary parts
steam flow excited vibration
as well as shaft vibration of generator's rotor exceeding the set standard etc.have successively appeared
the detailed diagnosis process and disposal measures being presented.The suddenly appeared low-frequency vibration of MP rotor is due to oil film whirling
the thermal bending of rotor resulted from impact-rubbing between movable and stationary parts is also the cause leading to increase of the vibration amplitude for MP rotor;the vibration of generator's rotor is resulted from impact-rubbing between the shaft-neck of rotor and the floating oil retainer
as well as unsmooth jamming between them.The adopted diagnosis and fault-disposing measures have reference value for vibration fault disposal on similar kind of untis.