TECHNICAL FEATURES OF PIPE-BLOWING ON ULTRA-SUPERCRITICAL 660 MW UNIT IN JINGGUANGSHAN POWER PLANT
|更新时间:2025-09-28
|
TECHNICAL FEATURES OF PIPE-BLOWING ON ULTRA-SUPERCRITICAL 660 MW UNIT IN JINGGUANGSHAN POWER PLANT
Thermal Power GenerationVol. 40, Issue 6, Pages: 41-43(2011)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK229.2
Published:2011
稿件说明:
移动端阅览
FU Longlong, MA Xiaolong, XIN Junfang, et al. TECHNICAL FEATURES OF PIPE-BLOWING ON ULTRA-SUPERCRITICAL 660 MW UNIT IN JINGGUANGSHAN POWER PLANT[J]. Thermal power generation, 2011, 40(6): 41-43.
DOI:
FU Longlong, MA Xiaolong, XIN Junfang, et al. TECHNICAL FEATURES OF PIPE-BLOWING ON ULTRA-SUPERCRITICAL 660 MW UNIT IN JINGGUANGSHAN POWER PLANT[J]. Thermal power generation, 2011, 40(6): 41-43.DOI:
TECHNICAL FEATURES OF PIPE-BLOWING ON ULTRA-SUPERCRITICAL 660 MW UNIT IN JINGGUANGSHAN POWER PLANT
摘要
介绍了华能井冈山电厂3号超超临界660 MW机组锅炉吹管过程及技术特点。因吹管时炉水循环泵未安装
故为在无炉水循环泵条件下的蒸汽吹管;使用相邻机组电动给水泵(电泵)
为无电泵机组吹管。锅炉疏水回收到除氧器
缓解了凝汽器不具备进水条件导致的吹管水量不足问题。虽与常规机组锅炉吹管条件不同
但吹管结果完全符合规范要求。
Abstract
The pipe-blowing process and its technical features for boiler of ultra-supercritical 660 MW unit no.3 in Huaneng Jinggangshan Power Plant have been presented.Owing to the boiler water circulating pump hadn't been installed at the time of pipe-blowing
therfore
it is called pipe-blowing using steam under condition without the boiler water circulating pump.By using the motor-driven feed-water pump of neighbouring unit
the pipe-blowing of unit without feed-water pump has been realized.The drain from boiler is reclaimed into the deaerator
alleviating the problem of having not enough water to carry out the pipe-blowing due to the condenser hasn't prepared for water-intaking.Though it is different from the pipe-blowing condition of boiler for conventional units
however
the effectiveness of pipe-blowing is fully conformed to the requirements defined in specifications
STUDY ON AND PRACTICE OF PIPE-BLOWING USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATION PUMP FOR ONCE-THROUGH BOILER OF ULTRA-SUPERITICAL 1 000 MW UNIT
SEVERAL PROBLEMS EXISTING IN OPERATION OF SUPERCRITICAL AND ULTRA-SUPERCRITICAL BOILERS
STUDY ON THE CONTROL MODEL OF INTERMEDIARY POINT TEMPERATURE IN BOILER OF ULTRA-SUPERCRITICAL UNIT BASED ON DYNAMIC MECHANISM ANALYSIS
NUMERICAL SIMULATION OF PULVERIZED COAL DISTRIBUTOR FORBOILER EQUIPPED FOR ULTRA-SUPERCRITICAL 1000 MW UNIT
OPTIMIZATION OF WATER SUPPLYING AND FLUSHING MODE FOR BOILER OF ULTRA-SUPERCRITICAL 1000 MW UNIT
Related Author
CUI Zhendong1
LI Xinhu1
YIN Fengjun2 1.Electric Power Science Research Institute under Guangdong Power Grid Corporation
WANG Meng-hao1
WANG Heng1
ZHENG Min-niu2
YANG Cong-xuan31.Shanghai Wangte Energy Science and Technology Co Ltd
FANG Yanjun1
Related Institution
Guangdong Power Grid Corporation Electric Power Science Research Institute
Guangdong Huizhou Pinghai Power Plant Co., Ltd
Shanghai Wangte Energy Technology Co., Ltd
Guodian Jianbi Power Plant