STUDY ON AND PRACTICE OF PIPE-BLOWING USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATION PUMP FOR ONCE-THROUGH BOILER OF ULTRA-SUPERITICAL 1 000 MW UNIT
|更新时间:2025-09-28
|
STUDY ON AND PRACTICE OF PIPE-BLOWING USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATION PUMP FOR ONCE-THROUGH BOILER OF ULTRA-SUPERITICAL 1 000 MW UNIT
Thermal Power GenerationVol. 40, Issue 7, Pages: 74-77(2011)
作者机构:
1. 广东电网公司电力科学研究院
2. 广东惠州平海发电厂有限公司
作者简介:
基金信息:
DOI:
CLC:TK229.2
Published:2011
稿件说明:
移动端阅览
CUI Zhendong1, LI Xinhu1, YIN Fengjun2 1.Electric Power Science Research Institute under Guangdong Power Grid Corporation. STUDY ON AND PRACTICE OF PIPE-BLOWING USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATION PUMP FOR ONCE-THROUGH BOILER OF ULTRA-SUPERITICAL 1 000 MW UNIT[J]. Thermal power generation, 2011, 40(7): 74-77.
DOI:
CUI Zhendong1, LI Xinhu1, YIN Fengjun2 1.Electric Power Science Research Institute under Guangdong Power Grid Corporation. STUDY ON AND PRACTICE OF PIPE-BLOWING USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATION PUMP FOR ONCE-THROUGH BOILER OF ULTRA-SUPERITICAL 1 000 MW UNIT[J]. Thermal power generation, 2011, 40(7): 74-77.DOI:
STUDY ON AND PRACTICE OF PIPE-BLOWING USING STEAM UNDER CONDITION WITHOUT BOILER WATER CIRCULATION PUMP FOR ONCE-THROUGH BOILER OF ULTRA-SUPERITICAL 1 000 MW UNIT
摘要
广东平海发电厂有限公司超超临界1 000MW机组直流锅炉采用832t/h最大保护直流流量
因炉水循环泵不能投运
导致机组起动阶段锅炉给水温度仅50℃左右
严重低于设计值(105℃)。对此
通过在锅炉起动排放系统上增加一路到除氧器的临时回收系统
实现了超超临界机组锅炉无炉水循环泵吹管
满足了机组冲转的参数要求。
Abstract
The once-through boiler of ultra-supercritical 1 000 MW unit in Guangdong Pinghai Power Plant Co Ltd
adopts maximum protecting once-through flow rate of 832 t/h
owing to the boiler water circulating pump(BWCP) can't be put into service
the feed-water temperature of boiler in the stage of start-up only can reach about 50 ℃
it is far lower than the designed value 105 ℃.For this
a temporary recovery system to the deaerator was added onto the discharging system during the time of boiler start-up
the pipe-blowing of ultra-supercritical unit under condition without BWCP has been realized
satisfying the requirement of parameters for rotation-impulsing.