STUDY ON REGULATION CHARACTERS OF TEMPERATURE RISE ON HEATING SURFACE IN LOW-TEMPERATURE SUPERHEATER OF THE EXTERNAL HEAT EXCHANGER EQUIPPED FOR ONE CFB BOILER
|更新时间:2025-09-28
|
STUDY ON REGULATION CHARACTERS OF TEMPERATURE RISE ON HEATING SURFACE IN LOW-TEMPERATURE SUPERHEATER OF THE EXTERNAL HEAT EXCHANGER EQUIPPED FOR ONE CFB BOILER
Thermal Power GenerationVol. 40, Issue 12, Pages: 43-48(2011)
作者机构:
1. 江西省电力科学研究院
2. 江西分宜发电有限责任公司
3. 西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK229.66
Published:2011
稿件说明:
移动端阅览
LIN Xianmin1, CHEN Wen1, WEI Youling2, et al. STUDY ON REGULATION CHARACTERS OF TEMPERATURE RISE ON HEATING SURFACE IN LOW-TEMPERATURE SUPERHEATER OF THE EXTERNAL HEAT EXCHANGER EQUIPPED FOR ONE CFB BOILER[J]. Thermal power generation, 2011, 40(12): 43-48.
DOI:
LIN Xianmin1, CHEN Wen1, WEI Youling2, et al. STUDY ON REGULATION CHARACTERS OF TEMPERATURE RISE ON HEATING SURFACE IN LOW-TEMPERATURE SUPERHEATER OF THE EXTERNAL HEAT EXCHANGER EQUIPPED FOR ONE CFB BOILER[J]. Thermal power generation, 2011, 40(12): 43-48.DOI:
STUDY ON REGULATION CHARACTERS OF TEMPERATURE RISE ON HEATING SURFACE IN LOW-TEMPERATURE SUPERHEATER OF THE EXTERNAL HEAT EXCHANGER EQUIPPED FOR ONE CFB BOILER
Directing against thirty operating conditions of one 670 t/h CFB boiler
measurement has been carried out
and adopting optimal regression analysis method
the regulation and control characters of temperature rise in divided return ash heat exchanger equipped with first-stage low-temperature superheater being analysed.Results show that the influence of parameters
such as loading rate of boiler
static pressure difference in upper part of the furnace
temperature of material returned into the cyclone
inlet steam temperature of the external heat exchanger
air flow rate in the distribution chamber
air flow rate in the internal flow-equalizing chamber
air flow rate in the external flow-equalizing chamber
and air flow rate in the heat exchanger etc.
upon temperature rise in the first-stage low-temperature superheater is not fully similar.The main regulation parameters of the first-stage lowtemperature superheater are air flow rate in the internal and external flow-equalizing chambers.Operation shows that the temperature rise in said low-temperature superheater regulated by air flow rate in said flow-equalizing chambers can satisfy the practical requirements.