ERROR ANALYSIS AND TECHNICAL RETROFIT OF DIFFERENTIAL PRESSURE WATER-LEVEL GAUGE FOR BOILER DRUM
|更新时间:2025-09-28
|
ERROR ANALYSIS AND TECHNICAL RETROFIT OF DIFFERENTIAL PRESSURE WATER-LEVEL GAUGE FOR BOILER DRUM
Thermal Power GenerationVol. 40, Issue 8, Pages: 61-63(2011)
作者机构:
广东国华惠州热电分公司
作者简介:
基金信息:
DOI:
CLC:TK223.6
Published:2011
稿件说明:
移动端阅览
WANG Zizhu Guangdong Guohua Huizhou Thermal Power Branch Company. ERROR ANALYSIS AND TECHNICAL RETROFIT OF DIFFERENTIAL PRESSURE WATER-LEVEL GAUGE FOR BOILER DRUM[J]. Thermal power generation, 2011, 40(8): 61-63.
DOI:
WANG Zizhu Guangdong Guohua Huizhou Thermal Power Branch Company. ERROR ANALYSIS AND TECHNICAL RETROFIT OF DIFFERENTIAL PRESSURE WATER-LEVEL GAUGE FOR BOILER DRUM[J]. Thermal power generation, 2011, 40(8): 61-63.DOI:
ERROR ANALYSIS AND TECHNICAL RETROFIT OF DIFFERENTIAL PRESSURE WATER-LEVEL GAUGE FOR BOILER DRUM
摘要
锅炉汽包差压式水位计在应用中普遍存在偏差大、失准等问题
通过对取压装置及补偿计算参数的分析
对其测量系统取样管及取样装置进行了改进
并对补偿计算参数进行了优化。改进和优化后
有效提高了差压式汽包水位计的稳定性和测量精确度。
Abstract
In application of the differential pressure water-level gauge for boiler drum
problems such as big deviation and unaccuracy are commonly existed.Through analysis of the pressure-taking device and the compensated computation parameters
the sampling tube and sampling facility of the measuring system have been retrofitted
and the compensated computation parameters being optimized.After retrofitting and optimization
the stability and measuring accuracy of the differential pressure water-level gauge for boiler drum have been effectively enhanced.