FREQUENCY CONVERSION RETROFIT OF CONDENSATE PUMP FOR 330 MW UNIT AND SYSTEM OPEATION OPTIMIZATION THEREOF
|更新时间:2025-09-28
|
FREQUENCY CONVERSION RETROFIT OF CONDENSATE PUMP FOR 330 MW UNIT AND SYSTEM OPEATION OPTIMIZATION THEREOF
Thermal Power GenerationVol. 40, Issue 9, Pages: 86-88(2011)
作者机构:
国电菏泽发电厂
作者简介:
基金信息:
DOI:
CLC:TM921.51
Published:2011
稿件说明:
移动端阅览
SHENG Xibing, LI Zhenqiang, DU Huazhong, et al. FREQUENCY CONVERSION RETROFIT OF CONDENSATE PUMP FOR 330 MW UNIT AND SYSTEM OPEATION OPTIMIZATION THEREOF[J]. Thermal power generation, 2011, 40(9): 86-88.
DOI:
SHENG Xibing, LI Zhenqiang, DU Huazhong, et al. FREQUENCY CONVERSION RETROFIT OF CONDENSATE PUMP FOR 330 MW UNIT AND SYSTEM OPEATION OPTIMIZATION THEREOF[J]. Thermal power generation, 2011, 40(9): 86-88.DOI:
FREQUENCY CONVERSION RETROFIT OF CONDENSATE PUMP FOR 330 MW UNIT AND SYSTEM OPEATION OPTIMIZATION THEREOF
摘要
国电菏泽电厂三期330 MW机组凝结水泵(凝泵)实施变频改造后
为了进一步降低凝结水管道的压力损失
机组正常运行时全开除氧器水位主、副调节阀及其旁路电动阀。为了满足汽动给水泵(汽泵)密封水压力的需要
适当开启汽泵密封水旁路阀
同时对凝结水系统控制逻辑进行了优化。优化后凝泵在变频运行方式下节电效果明显
机组安全性得到进一步提高。
Abstract
After implementation of frequency conversion retrofit for condensate pumps of 330 MW untis in the third-phase poject of Guodian Heze Power Plant
in order to further reduce the pressure loss in the condensate pipeline
the main and auxiliary regulating valves for water-level in the deaerator as well as its bypass motor-operated valve are fully opened during normal operation of units.For satisfying the requirement of sealing water pressure in the turbine-driven feed-water pump
the sealing water bypass valve of turbine-driven feed-water pump has to be properly opened.At the same time
the control logic of condensate system has been optimized.After optimization
the effectivenes of electricity-saving is remarkable under operation mode of frequency conversion
ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA
REALIZATION OF ZERO SPECIFIC CONSUMPTION FOR CONDENSATE PUMPS,CIRCULATING-WATER PUMPS,AND MOTOR-DRIVEN FEED-WATER PUMPS DURING START-UP PROCESS OF 300MW UNITS
FREQUENCY CONVERSION RETROFIT AND ENERGY-SAVING OF CONDENSATE PUMP IN HUAYU POWER PLANT
ANALYSIS ABOUT ECONOMIC EFFICIENCY OF ONE 330 MW UNIT AFTER INCREASING CAPACITY THROUGH THROTTLING EXTRACTED STEAM FROM HIGH-PRESSURE HEATERS