STUDY ON IRON REMOVAL PERFORMANCE OF NEW TYPE HIGH GRADIENT ELECTRO-MAGNETIC FILTER
|更新时间:2025-09-28
|
STUDY ON IRON REMOVAL PERFORMANCE OF NEW TYPE HIGH GRADIENT ELECTRO-MAGNETIC FILTER
Thermal Power GenerationVol. 40, Issue 9, Pages: 42-44(2011)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2011
稿件说明:
移动端阅览
YE Zhou, LI Nan, TIAN Wenhua, et al. STUDY ON IRON REMOVAL PERFORMANCE OF NEW TYPE HIGH GRADIENT ELECTRO-MAGNETIC FILTER[J]. Thermal power generation, 2011, 40(9): 42-44.
DOI:
YE Zhou, LI Nan, TIAN Wenhua, et al. STUDY ON IRON REMOVAL PERFORMANCE OF NEW TYPE HIGH GRADIENT ELECTRO-MAGNETIC FILTER[J]. Thermal power generation, 2011, 40(9): 42-44.DOI:
STUDY ON IRON REMOVAL PERFORMANCE OF NEW TYPE HIGH GRADIENT ELECTRO-MAGNETIC FILTER
Adopting the water sample prepared from actual corrosion products of iron in power plants
the performance of home-made new type(CAD) high gradient electro-magnetic filter has been tested.Results show that the iron content in effluent water is 2.5 μg/L
while that in inffluent water is 20 μg/L under condition of the rated flow rate in said CAD filter being 10 m3/h(flow speed 266 m/h)
the iron removal rate is 86.8%
the iron content in effluent water reaching the water quality standard of 5μg/L iron content in feed-water of supercritical once-through boiler specified in GB/T 12145—2008 《The water-steam quality of thermal power units and steam power equipments》.In the case of iron content in inffluent water being 40
185
700
and 1500 μg/L respectively
the iron content in effluent water is 7.6
12.2
18.1
and 26.2 μg/L respectively
the iron removal rate is 81.4%
93.4%
97.4%
and 98.3% respectively.Excepting the CAD high gradient electro-magnetic filter can remove the ferromagnetic corrosion products
its removal efficiency for paramagnetic corrosion products is also higher.