STUDY ON SECTIONAL MODEL OF BUILT-IN TYPE DEAERATOR
|更新时间:2025-09-28
|
STUDY ON SECTIONAL MODEL OF BUILT-IN TYPE DEAERATOR
Thermal Power GenerationVol. 41, Issue 1, Pages: 26-30(2012)
作者机构:
华中科技大学能源与动力工程学院
作者简介:
基金信息:
DOI:
CLC:TK223.522
Published:2012
稿件说明:
移动端阅览
ZHAO Yunyun, ZHANG Yanping, HUANG Shuhong, et al. STUDY ON SECTIONAL MODEL OF BUILT-IN TYPE DEAERATOR[J]. Thermal power generation, 2012, 41(1): 26-30.
DOI:
ZHAO Yunyun, ZHANG Yanping, HUANG Shuhong, et al. STUDY ON SECTIONAL MODEL OF BUILT-IN TYPE DEAERATOR[J]. Thermal power generation, 2012, 41(1): 26-30.DOI:
STUDY ON SECTIONAL MODEL OF BUILT-IN TYPE DEAERATOR
On the basis of traditional lumped parameter model of the deaerator
a sectional model of the build-in type deaerater
including sub-models such as that in spraying section
mixed heat exchanger section
and the bubbling section
as well as the arrangement of steam flowing pipes in the deaerator
has been established
reflecting the influence of internal structure and working process
such as arrangement of steam flowing pipes and atomization using nozzles
upon the thermodynamic performance of the said deaerator.Taking the deaerator of one supercritical 600 MW unit as an example
the working situation of deaerator under different designed operating conditions have been simulated by using the sectional model and the non-sectional model respectively.Results show that the accuracy and stability of the sectional model are far higher than that of the traditional non-sectional model
being able to be used for analysing the thermodynamic behavior of deaerator.