OPTIMIZATION OF TEST CONDITIONS FOR EVALUATING SCALE-INHIBITOR'S PERFORMANCE BY USING CONSTANT POTENTIAL CATHODIC POLARIZATION METHOD
|更新时间:2025-09-28
|
OPTIMIZATION OF TEST CONDITIONS FOR EVALUATING SCALE-INHIBITOR'S PERFORMANCE BY USING CONSTANT POTENTIAL CATHODIC POLARIZATION METHOD
Thermal Power GenerationVol. 41, Issue 1, Pages: 12-15(2012)
作者机构:
1. 上海电力学院热交换系统节能工程技术研究中心
2. 同济大学化学系
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2012
稿件说明:
移动端阅览
LIN Jianzhen1, LIANG Lei1, LI Mingli2, et al. OPTIMIZATION OF TEST CONDITIONS FOR EVALUATING SCALE-INHIBITOR'S PERFORMANCE BY USING CONSTANT POTENTIAL CATHODIC POLARIZATION METHOD[J]. Thermal power generation, 2012, 41(1): 12-15.
DOI:
LIN Jianzhen1, LIANG Lei1, LI Mingli2, et al. OPTIMIZATION OF TEST CONDITIONS FOR EVALUATING SCALE-INHIBITOR'S PERFORMANCE BY USING CONSTANT POTENTIAL CATHODIC POLARIZATION METHOD[J]. Thermal power generation, 2012, 41(1): 12-15.DOI:
OPTIMIZATION OF TEST CONDITIONS FOR EVALUATING SCALE-INHIBITOR'S PERFORMANCE BY USING CONSTANT POTENTIAL CATHODIC POLARIZATION METHOD
Taking the most commonly used 304 stainless steel in condensers of power plants as the test samples
the main affecting factors upon adopting the constant potential cathodic polarization method for evaluating scale-inhibitor's performance have been determined.Results show that the sequence of main affecting factors is listed as in the following:the potential of polarization
the concentration of ions for scale formation
the time of polarization
and the temperature for polarization.The test conditions after optimization are:the polarization voltage-1.040 V
CaCl2 9.0 mmol/L NaHCO3 18.0 mmol/L
the polarization time 4 h
the reaction temperature 45.0 ℃.After optimization of the test conditions
the relative error in measurement of scale-inhibiting rate reduced 42%
the distinguishability being substantially enhanced.