CAUSE ANALYSIS OF CONTINUOUS TUBE BURST ON HOLDING PIPES OF THE SCREEN-TYPE REHEATER FOR BOILER NO1 IN ONE POWER PLANT
|更新时间:2025-09-28
|
CAUSE ANALYSIS OF CONTINUOUS TUBE BURST ON HOLDING PIPES OF THE SCREEN-TYPE REHEATER FOR BOILER NO1 IN ONE POWER PLANT
Thermal Power GenerationVol. 41, Issue 2, Pages: 88-90(2012)
作者机构:
甘肃电力科学研究院
作者简介:
基金信息:
DOI:
CLC:TK228
Published:2012
稿件说明:
移动端阅览
ZHAO Mingzhong, WU Kai Gansu Electric Power Science Research Institute. CAUSE ANALYSIS OF CONTINUOUS TUBE BURST ON HOLDING PIPES OF THE SCREEN-TYPE REHEATER FOR BOILER NO1 IN ONE POWER PLANT[J]. Thermal power generation, 2012, 41(2): 88-90.
DOI:
ZHAO Mingzhong, WU Kai Gansu Electric Power Science Research Institute. CAUSE ANALYSIS OF CONTINUOUS TUBE BURST ON HOLDING PIPES OF THE SCREEN-TYPE REHEATER FOR BOILER NO1 IN ONE POWER PLANT[J]. Thermal power generation, 2012, 41(2): 88-90.DOI:
CAUSE ANALYSIS OF CONTINUOUS TUBE BURST ON HOLDING PIPES OF THE SCREEN-TYPE REHEATER FOR BOILER NO1 IN ONE POWER PLANT
摘要
对某电厂发电机组锅炉屏式再热器(屏再)夹持管连续多次爆管原因进行了分析
认为在焊接过程中未能严格执行焊接工艺要求
致使焊接接头的热影响区产生晶粒粗大和黑色网状晶界的不良组织
并且焊后热处理不当使熔合线产生了沿晶裂纹
这些裂纹在机组运行过程中逐渐扩展造成管子沿焊缝熔合线开裂。对此
建议加强设备监造
对重要的承压部件进行无损探伤抽检和理化性能试验。
Abstract
The causes leading to continuous and frequent tube bursts on holding pipes of screen-typ reheater for boiler no1 in one power plant have been analysed
it is believed that the requirements of welding process hadn't strictly implemented during the course of welding
resulting in bad structure of coase-grained and black-reticulated grain boundaries appeared in the heat affecting areas of welded joints.Owing to unsuitable heat treatment after welding
the along-crystalline cracks are occurred on fusion lines
these cracks expand in operation
resulting in rupture along fusion line of the welding joints on pipes.It is recommented to further strengthen the supervision in manufacturing the equipments
and to carry out non-destructive inspection and physico-chemical test for the important pressurized parts.
STUDY ON SERVICING BEHAVIOR OF BOILER TUBES MADE FROM 18-8 TYPE AUSTENITIC STAINLESS STEEL(6)
CAUSE ANALYSIS OF DESUPERHEATER FRACTURE FOR BOILER OF 600 MW UNIT
ANALYSIS OF OVERTEMPERATURE PROBLEM OCCURRED ON PIPE WALL OF HIGH-TEPERATURE HEATING SURFACE FOR BOILERS IN ZHUHAI POWER PLANT AND SOLVING SCHEME THEREOF
Study on blowing process of oxide skin of steam pipeline in a 1000 MW unit
THE CARBIDE CONTAINED IN HCM25(T23) STEEL AND EVOLUTION REGULARITY THEREOF
Related Author
MA Hong
ZHANG Lei
ZHENG Fangping
HE Xipeng
SHI Zhigang
WANG Hongzhe Xi'an Thermal Power Research Institute Co Ltd
LIU Feng
YAN Kai-ping
Related Institution
Xi'an Thermal Power Research Institute Co., Ltd
Datang Panshan Power Generation Co., Ltd
Guangqian Electric Power Co., Ltd
Shaanxi Energy Zhaoshipan Coal and Electricity Co., Ltd
Guangdong Power Grid Corporation Electric Power Science Research Institute