NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS
|更新时间:2025-09-28
|
NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS
Thermal Power GenerationVol. 41, Issue 3, Pages: 68-70(2012)
作者机构:
上海电力修造总厂有限公司
作者简介:
基金信息:
DOI:
CLC:TH38
Published:2012
稿件说明:
移动端阅览
PAN Guomin, ZHENG Yu, CHEN Naijuan Shanghai Electric Power Equipment Repair and Manufacture Works Co Ltd. NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS[J]. Thermal power generation, 2012, 41(3): 68-70.
DOI:
PAN Guomin, ZHENG Yu, CHEN Naijuan Shanghai Electric Power Equipment Repair and Manufacture Works Co Ltd. NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS[J]. Thermal power generation, 2012, 41(3): 68-70.DOI:
NUMERICAL CALCULATION OF THREE-DIMENSIONAL FLOW FIELD IN FEED-WATER PUMP OF BOILER EQUIPPED WITH ULTRA-SUPERCRITICAL UNITS
and adopting the standard k-ε turbulence model and the upgradable wall-surface function metod
a three-dimensional steady turbulent flow field in the feed-water pump of boiler equipped with 1 000 MW unit has been calculated
the velocity and pressure distribution of flow field within the main parts
namely impeller and guide vanes
being achieved.Analysis of numerical calculation results and the predicted characteristic curves of the feed-water pump show that the relative error between the predicted discharge head of said feed-water pump and the tested value is in a range of 1.8%~7.8%
and the relative error between the predicted efficiency of feed-water pump and the tested value is in a range of 3.85%~6.3%