MODELLING AND EMULATION ANALYSIS OF UNITS MIXEDLY BURNING BLAST FURNACE GAS AND COAL IN THERMAL POWER PLANT
|更新时间:2025-09-28
|
MODELLING AND EMULATION ANALYSIS OF UNITS MIXEDLY BURNING BLAST FURNACE GAS AND COAL IN THERMAL POWER PLANT
Thermal Power GenerationVol. 41, Issue 4, Pages: 59-64(2012)
作者机构:
上海交通大学机械与动力工程学院
作者简介:
基金信息:
DOI:
CLC:TM621.3
Published:2012
稿件说明:
移动端阅览
ZHANG Weiwei, ZHANG Huisheng, SU Ming College of Mechanical and Power Engineering. MODELLING AND EMULATION ANALYSIS OF UNITS MIXEDLY BURNING BLAST FURNACE GAS AND COAL IN THERMAL POWER PLANT[J]. Thermal power generation, 2012, 41(4): 59-64.
DOI:
ZHANG Weiwei, ZHANG Huisheng, SU Ming College of Mechanical and Power Engineering. MODELLING AND EMULATION ANALYSIS OF UNITS MIXEDLY BURNING BLAST FURNACE GAS AND COAL IN THERMAL POWER PLANT[J]. Thermal power generation, 2012, 41(4): 59-64.DOI:
MODELLING AND EMULATION ANALYSIS OF UNITS MIXEDLY BURNING BLAST FURNACE GAS AND COAL IN THERMAL POWER PLANT
摘要
根据某电厂350 MW机组热力系统的特点建立了热力系统仿真模型
在机组满负荷下
对锅炉燃烧煤+低热值高炉煤气工况进行的仿真结果表明
主要参数均与机组实际运行参数相符。在此基础上
针对锅炉混烧低热值煤气存在的排烟温度高等问题进行了分析
提出了适当增加空气预热器换热面积降低排烟温度、提高锅炉效率的改进措施。
Abstract
Based on the features of thermodynamic system for the 350 MW unit in one power plant
the emulation model for said system has been established.Results of emulation under condition of mixedly burning coal and blast furnace gas of low calorific value show that the main parameters tally with the actual parameters in operation of unit.On the basis of this
directing against the problems of high discharged flue gas temperature etc.existing in mixedly burning
analysis has been carried out
and improvement measure of suitably increasing the heat exchange area of air preheater has been put forward
so as to reduce the discharged flue gas temperature and enhance the boiler effciency.