SOLUTION MEASURES FOR WIND-SNATCHING AND SHAFT VIBRATION OCCURRED EASILY IN RETROFIT OF AIR FANS
|更新时间:2025-09-28
|
SOLUTION MEASURES FOR WIND-SNATCHING AND SHAFT VIBRATION OCCURRED EASILY IN RETROFIT OF AIR FANS
Thermal Power GenerationVol. 41, Issue 6, Pages: 38-40(2012)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TH43
Published:2012
稿件说明:
移动端阅览
LIU Jiayu Xi'an Thermal Power Research Institute Co Ltd. SOLUTION MEASURES FOR WIND-SNATCHING AND SHAFT VIBRATION OCCURRED EASILY IN RETROFIT OF AIR FANS[J]. Thermal power generation, 2012, 41(6): 38-40.
DOI:
LIU Jiayu Xi'an Thermal Power Research Institute Co Ltd. SOLUTION MEASURES FOR WIND-SNATCHING AND SHAFT VIBRATION OCCURRED EASILY IN RETROFIT OF AIR FANS[J]. Thermal power generation, 2012, 41(6): 38-40.DOI:
SOLUTION MEASURES FOR WIND-SNATCHING AND SHAFT VIBRATION OCCURRED EASILY IN RETROFIT OF AIR FANS
and torsional vibration of shaft etc.occurred easily in energy-saving retrofit of air fans at present in our country have been analysed
and solution measures being put forward as in the following:before retrofit
measures should be taken from aspects of design and opration to prevent the wind-snatching phenominon between two air fans in parallel operation;calculation of natural vibration frequency for various parts
such as impeller
blade
as well as front
rear
and middle disks in centrifugal air fans
to keep away from resonance frequency
if resonance has occurred at one revolution speed
operation at this speed should be avoided
or adopting regulation valve
combined with adjustment of revolution speed
to prevent resonace of air fans;in order to prevent the torsional vibration of shaf in air fans with speed regulation by variable frequency
the inherent frequency of forsional vibration should be calculated before retrofit
preventing the torsional frequency to fall into the speed-regulating range of air fans.