DETERMINATION OF VARIOUS ANIONS IN NATURAL WATER BY GRADIENT ELUTION LON CHROMATOGRAPHY
|更新时间:2025-09-28
|
DETERMINATION OF VARIOUS ANIONS IN NATURAL WATER BY GRADIENT ELUTION LON CHROMATOGRAPHY
Thermal Power GenerationVol. 41, Issue 8, Pages: 41-44(2012)
作者机构:
武汉大学动力与机械学院
作者简介:
基金信息:
DOI:
CLC:TM621.8
Published:2012
稿件说明:
移动端阅览
ZHAN Yi, CAO Shun'an, HAN Qianqian College of Power and Mechanical Engineering. DETERMINATION OF VARIOUS ANIONS IN NATURAL WATER BY GRADIENT ELUTION LON CHROMATOGRAPHY[J]. Thermal power generation, 2012, 41(8): 41-44.
DOI:
ZHAN Yi, CAO Shun'an, HAN Qianqian College of Power and Mechanical Engineering. DETERMINATION OF VARIOUS ANIONS IN NATURAL WATER BY GRADIENT ELUTION LON CHROMATOGRAPHY[J]. Thermal power generation, 2012, 41(8): 41-44.DOI:
DETERMINATION OF VARIOUS ANIONS IN NATURAL WATER BY GRADIENT ELUTION LON CHROMATOGRAPHY
PO43-in natural water was established.Gradient elution was performed by using the IonPac AS17-C analytical column
and the KOH eluent was online generated by EG40.The flow rate was 1.0 mL/min
column temperature was 30 ℃
and the injection volume was 25μL.Results show that
the ion detection limits are distributed within 0.5~3.1 μg/L
and the relative standard deviation(RSD) is less than 0.92%;test recovery rate for actual natural water sample is from 95.2% to101.8%.Because it is sensitive
fast and accurate
this gradient elution method applies to simultaneous determination of multiple anions in natural water.