TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER
|更新时间:2025-09-28
|
TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER
Thermal Power GenerationVol. 41, Issue 4, Pages: 36-39(2012)
作者机构:
内蒙古科技大学能源与环境学院
作者简介:
基金信息:
DOI:
CLC:TK229.6
Published:2012
稿件说明:
移动端阅览
LI Haiguang, ZHAO Zengwu, LI Ke, et al. TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER[J]. Thermal power generation, 2012, 41(4): 36-39.
DOI:
LI Haiguang, ZHAO Zengwu, LI Ke, et al. TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER[J]. Thermal power generation, 2012, 41(4): 36-39.DOI:
TEST STUDY ON WORKING BEHAVIOR OF J-TYPE VALVE USED FOR CFB BOILER
The J-type valve is a kind of facility used frequently to return materials into risers in CFB boilers
its working behavior is very important for ensuring normal operation of the CFB boiler.A method for analysing and evaluating the working behavior of J-type valve based on pressure difference on key parts in the CFB boiler
such as the pressure difference of material layer in the riser
the pressure difference between air quantity in returned material and the main air compartment
and the pressure difference of material layer in the furnace etc.
has been put forward
and the said method being tested on the cold-state test stand.Results of test show that the measurement of pressure difference variation on key location in the furnace is helpful to undestand the working behavier of the J-type valve
providing method and measure for solving the problems