EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER
|更新时间:2025-09-28
|
EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER
Thermal Power GenerationVol. 41, Issue 10, Pages: 13-17(2012)
作者机构:
1. 华北电力大学能源动力与机械工程学院
2. 中国电力企业联合会科技开发服务中心
作者简介:
基金信息:
DOI:
CLC:TK229.66
Published:2012
稿件说明:
移动端阅览
LI Bin1, 2, LI Jianfeng2, et al. EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER[J]. Thermal power generation, 2012, 41(10): 13-17.
DOI:
LI Bin1, 2, LI Jianfeng2, et al. EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER[J]. Thermal power generation, 2012, 41(10): 13-17.DOI:
EXERGY ANALYSIS FOR EFFICIENCY ENHANCEMENT OF THE 135 MW UNIT WITH CFB BOILER
The exergy efficiency and loss of each link in power generation was revealed by exergy analysis for efficiency of a 135 MW unit with circulating fluidized bed(CFB) boiler.Results show that
for the135 MW unit that working with the CFB boiler
the exergy loss during combustion and heat transfer process are the two maximum parts of all exergy losses.Meanwhile
to improve the performance of the unit system
methods for decreasing such indexes as the exergy loss during combustion and heat transfer
the condenser backpressure and carbon content in fly ash etc.are discussed.