ARTIFICIAL NEURAL NETWORK BASED ON-LINE MONITORING OF FOULING AND SLAGGING ON HEATING SURFACE OF COAL-FIRED BOILER
|更新时间:2025-09-28
|
ARTIFICIAL NEURAL NETWORK BASED ON-LINE MONITORING OF FOULING AND SLAGGING ON HEATING SURFACE OF COAL-FIRED BOILER
Thermal Power GenerationVol. 41, Issue 9, Pages: 99-102(2012)
作者机构:
华北电力大学电站设备状态监测与控制教育部重点实验室
作者简介:
基金信息:
DOI:
CLC:TK31
Published:2012
稿件说明:
移动端阅览
ZHU Xinwei, SUN Baomin, DU Xu, et al. ARTIFICIAL NEURAL NETWORK BASED ON-LINE MONITORING OF FOULING AND SLAGGING ON HEATING SURFACE OF COAL-FIRED BOILER[J]. Thermal power generation, 2012, 41(9): 99-102.
DOI:
ZHU Xinwei, SUN Baomin, DU Xu, et al. ARTIFICIAL NEURAL NETWORK BASED ON-LINE MONITORING OF FOULING AND SLAGGING ON HEATING SURFACE OF COAL-FIRED BOILER[J]. Thermal power generation, 2012, 41(9): 99-102.DOI:
ARTIFICIAL NEURAL NETWORK BASED ON-LINE MONITORING OF FOULING AND SLAGGING ON HEATING SURFACE OF COAL-FIRED BOILER
pollution status on-line monitoring model for heating surface was established by taking a 300 MW unit boiler as the object.Based on artificial neutral network(ANN)
cleaness coefficient F was introduced to represent the fouling condition of heating surface
and the calculation methods of F was discussed respectively
according to different surfaces such as high/low temperature convection heating surface and water wall.A parameter diagnosis model was established for sample data preprocessing to remove "bad values" and ensure the reality and continuity of thermal parameters.Analysis on ash accumulation curves of water wall area around RN01 soot blower and the low temperature superheater indicates that
the variation of cleaness coefficient is in accordance with the actual soot blowing situation.After soot blowing
the F increases dramatically.But as the operation time extending without soot blowing
it drops back to the normal value.This online model can reflect the actual pollution status of heating surface