WATER CONSUMPTION OF WET FGD DEVICE FOR 600 MW UNITS
|更新时间:2025-09-28
|
WATER CONSUMPTION OF WET FGD DEVICE FOR 600 MW UNITS
Thermal Power GenerationVol. 41, Issue 10, Pages: 35-37(2012)
作者机构:
河北大唐国际王滩发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:X773
Published:2012
稿件说明:
移动端阅览
NIE Pengfei, WANG Yang, WU Xuemin Heibei Datang International Wangtan Power Generation Co.Ltd.. WATER CONSUMPTION OF WET FGD DEVICE FOR 600 MW UNITS[J]. Thermal power generation, 2012, 41(10): 35-37.
DOI:
NIE Pengfei, WANG Yang, WU Xuemin Heibei Datang International Wangtan Power Generation Co.Ltd.. WATER CONSUMPTION OF WET FGD DEVICE FOR 600 MW UNITS[J]. Thermal power generation, 2012, 41(10): 35-37.DOI:
WATER CONSUMPTION OF WET FGD DEVICE FOR 600 MW UNITS
The application and consumption of process water for desulfurization device were analyzed and calculated
based on actual operating data of limestone-gypsum wet flue gas desulfurization equipment for a 600 MW unit under full load condition
and the water balance diagram was established
too.Analysis indicates that
the water balance of desulfurization system is closely related to parameters such as flue gas flow of the boiler
inlet and outlet temperature of the desulfurization unit
and so on.The quantity of evaporated water in the absorber accounts for more than 90 percent of the system water consumption.Finally
the corresponding water-saving measures are put forward.For example
lower the temperature of inlet gas;use low-temperature economizer;introduce coal-washing water into limestone slurry making;collect and make use of condensate water in the chimney and flue