EXPERIMENTAL STUDY ON PERFORMANCE OF WELDED POINT BETWEEN DOMESTIC S30432 STEEL PIPE AND T92 DISSIMILAR STEEL
|更新时间:2025-09-28
|
EXPERIMENTAL STUDY ON PERFORMANCE OF WELDED POINT BETWEEN DOMESTIC S30432 STEEL PIPE AND T92 DISSIMILAR STEEL
Thermal Power GenerationVol. 41, Issue 8, Pages: 91-97(2012)
作者机构:
神华国华(北京)电力研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TG407
Published:2012
稿件说明:
移动端阅览
LIANG Jun Shenhua Guohua(Beijing) Electric Power Research Institute Co.. EXPERIMENTAL STUDY ON PERFORMANCE OF WELDED POINT BETWEEN DOMESTIC S30432 STEEL PIPE AND T92 DISSIMILAR STEEL[J]. Thermal power generation, 2012, 41(8): 91-97.
DOI:
LIANG Jun Shenhua Guohua(Beijing) Electric Power Research Institute Co.. EXPERIMENTAL STUDY ON PERFORMANCE OF WELDED POINT BETWEEN DOMESTIC S30432 STEEL PIPE AND T92 DISSIMILAR STEEL[J]. Thermal power generation, 2012, 41(8): 91-97.DOI:
EXPERIMENTAL STUDY ON PERFORMANCE OF WELDED POINT BETWEEN DOMESTIC S30432 STEEL PIPE AND T92 DISSIMILAR STEEL
short time strengthen/ ductility under room or high temperature
impact toughness
processing property
microstructure examination
mechanical properties of fracture
aging test and high temperature endurance test were conducted to evaluate the performance of welded joint between S30432 steel pipe and T92 dissimilar steel.Moreover
the results were compared with that of the imported SUPER304H steel pipe and T92 dissimilar steel.It shows that
for welded joint between S30432 steel pipe and T92 dissimilar steel
its weldability and short term performance can satisfy the requirements of DL/T 868—2004
DL/T 751—2001
and other relevant standards.Meanwhile
its performance is as well as that of SUPER304H+T92 prepared at the same batch or packed from Japan.