ENERGY-SAVING TRANSFORMATION OF ROTARY AIR PREHEATER FOR BOILER ON A 600 MW UNIT
|更新时间:2025-09-28
|
ENERGY-SAVING TRANSFORMATION OF ROTARY AIR PREHEATER FOR BOILER ON A 600 MW UNIT
Thermal Power GenerationVol. 41, Issue 10, Pages: 64-65(2012)
作者机构:
河南电力试验研究院
作者简介:
基金信息:
DOI:
CLC:TM621.2
Published:2012
稿件说明:
移动端阅览
ZHANG Buting, WANG Chunyu, LI Ling, et al. ENERGY-SAVING TRANSFORMATION OF ROTARY AIR PREHEATER FOR BOILER ON A 600 MW UNIT[J]. Thermal power generation, 2012, 41(10): 64-65.
DOI:
ZHANG Buting, WANG Chunyu, LI Ling, et al. ENERGY-SAVING TRANSFORMATION OF ROTARY AIR PREHEATER FOR BOILER ON A 600 MW UNIT[J]. Thermal power generation, 2012, 41(10): 64-65.DOI:
ENERGY-SAVING TRANSFORMATION OF ROTARY AIR PREHEATER FOR BOILER ON A 600 MW UNIT
Poor heat transfer effect of the rotary air preheater was considered as the main reason for the phenomenon occurs in a 600 MW ultra supercritical unit boiler:low hot air temperature and high exhaust gas temperature.To solve this problem
300 mm height carbon steel heat storage component was added to the heat section of preheater.Results show that
heat transfer is significantly enhanced.Temperature rise of the primary and secondary air
and its drop of the delayed side both meets the design value.Heat exchange efficiency of the flue gas side reaches 70.78%