HIGH EXHAUST GAS TEMPERATURE OF 330 MW UNIT BOILER IN SHENHUA GUOHUA HUIZHOU THERMAL POWER PLANT: REASON ANALYSIS AND COUNTERMEASURES
|更新时间:2025-09-28
|
HIGH EXHAUST GAS TEMPERATURE OF 330 MW UNIT BOILER IN SHENHUA GUOHUA HUIZHOU THERMAL POWER PLANT: REASON ANALYSIS AND COUNTERMEASURES
Thermal Power GenerationVol. 41, Issue 9, Pages: 85-87(2012)
作者机构:
神华国华惠州热电分公司
作者简介:
基金信息:
DOI:
CLC:TK227
Published:2012
稿件说明:
移动端阅览
ZOU Haifeng China Shenhua Energy Co.. HIGH EXHAUST GAS TEMPERATURE OF 330 MW UNIT BOILER IN SHENHUA GUOHUA HUIZHOU THERMAL POWER PLANT: REASON ANALYSIS AND COUNTERMEASURES[J]. Thermal power generation, 2012, 41(9): 85-87.
DOI:
ZOU Haifeng China Shenhua Energy Co.. HIGH EXHAUST GAS TEMPERATURE OF 330 MW UNIT BOILER IN SHENHUA GUOHUA HUIZHOU THERMAL POWER PLANT: REASON ANALYSIS AND COUNTERMEASURES[J]. Thermal power generation, 2012, 41(9): 85-87.DOI:
HIGH EXHAUST GAS TEMPERATURE OF 330 MW UNIT BOILER IN SHENHUA GUOHUA HUIZHOU THERMAL POWER PLANT: REASON ANALYSIS AND COUNTERMEASURES
摘要
对国华惠州热电厂330MW机组WGZ1100/17.45-3型锅炉排烟温度偏高的原因进行了分析
认为其主要因炉膛本体及制粉系统漏风、磨煤机一次风掺冷风量过多、炉内结焦和受热面积灰等所致。对此
提出了增加空气预热器面积
利用一次风和排烟加热凝结水等措施
实施后排烟温度明显下降。
Abstract
Serious high exhaust gas temperature occurred on WGZ1100/17.45-3 type boiler of 330 MW unit in Guohua Huizhou Thermal Power Plant.After analysis
air leakage in furnace and the corresponding system
too much cold air entering the coal pulverizer
slagging and fouling on heating surface were considered as the main reasons.Thus
several countermeasures were carried out
such as increasing the heating surface area of preheater
heating the condensate water by primary air and exhaust gas etc.Through these improvements