Characteristic flow area based fault diagnosis for flow passage fouling of steam turbines
|更新时间:2025-09-28
|
Characteristic flow area based fault diagnosis for flow passage fouling of steam turbines
Thermal Power GenerationVol. 42, Issue 2, Pages: 92-94(2013)
作者机构:
1. 华北电力大学能源动力与机械工程学院
2. 河北省电力研究院
作者简介:
基金信息:
DOI:
CLC:TM311
Published:2013
稿件说明:
移动端阅览
BING Hankun1, DING Changfu1, LU Shengyang2, et al. Characteristic flow area based fault diagnosis for flow passage fouling of steam turbines[J]. Thermal power generation, 2013, 42(2): 92-94.
DOI:
BING Hankun1, DING Changfu1, LU Shengyang2, et al. Characteristic flow area based fault diagnosis for flow passage fouling of steam turbines[J]. Thermal power generation, 2013, 42(2): 92-94.DOI:
Characteristic flow area based fault diagnosis for flow passage fouling of steam turbines
摘要
基于汽轮机特征通流面积(CFA)概念
给出了特征通流面积及其变化率的计算公式
并采用该公式对某亚临界300MW机组大修前、后汽轮机部分级组的特征通流面积及其变化率进行了计算
确定该汽轮机中压缸通流部分发生结垢。该结果与实际情况相符
表明汽轮机特征通流面积可以作为汽轮机通流部分故障诊断的依据。
Abstract
Based on the conception of characteristic flow area(CFA) of steam turbines
the formulas of the CFA and its change rate were derived and adopted to conduct calculation for turbine before and after major overhaul in a sub-critical 300 MW unit.Results indicated that fouling occurred in flow passage of the intermediate pressure cylinder in this turbine
which was in accordance with the actual situation.Therefore
the CFA can be used as the basis for fault diagnosis for flow passage of turbines.