Corrosion characteristics of superheater subjected to gas phase in waste plastic fired boilers
|更新时间:2025-09-28
|
Corrosion characteristics of superheater subjected to gas phase in waste plastic fired boilers
Thermal Power GenerationVol. 42, Issue 8, Pages: 119-123(2013)
作者机构:
东南大学能源热转换及其过程测控教育部重点实验室
作者简介:
基金信息:
DOI:
CLC:TK224.9
Published:2013
稿件说明:
移动端阅览
SANG Shenghuan, DUAN Yufeng, CHEN Huichao, et al. Corrosion characteristics of superheater subjected to gas phase in waste plastic fired boilers[J]. Thermal power generation, 2013, 42(8): 119-123.
DOI:
SANG Shenghuan, DUAN Yufeng, CHEN Huichao, et al. Corrosion characteristics of superheater subjected to gas phase in waste plastic fired boilers[J]. Thermal power generation, 2013, 42(8): 119-123.DOI:
Corrosion characteristics of superheater subjected to gas phase in waste plastic fired boilers
The corrosion weight method was adopted to investigate the corrosion characteristics of G20
the common material for superheaters in low parameter CFB boilers in tube furnace under simulated flue gas condition
with different HCl concentrations(from 0.1%to 0.2%)and temperatures(from 500℃to 600℃).Metal specimens after corrosion tests were analyzed by SEMEDS and XRD to detect the appearance and composition of corrosion products.Moreover
kinetic analysis was also conducted.The results showed that
with an increase in the reaction temperature and HCl concentration
the anti-corrosion performance of 20Gdecreased generally.The corrosion film on metal surface showed a layered structure;the content of Cl decreased from inside to outside
and the outside layer mainly consisted of Fe2O3and a small amount of Fe3O4.The corrosion products took on a needle-like structure at 0.1% HCl concentration and this shape became bigger when the temperature increased.Therefore