Transformation and optimization of baghouses of two 300t/h CFB boilers
|更新时间:2025-09-28
|
Transformation and optimization of baghouses of two 300t/h CFB boilers
Thermal Power GenerationVol. 42, Issue 9, Pages: 125-129(2013)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:X701.2
Published:2013
稿件说明:
移动端阅览
NIE Xiaofeng, LI Dongyang, LIU Yuan, et al. Transformation and optimization of baghouses of two 300t/h CFB boilers[J]. Thermal power generation, 2013, 42(9): 125-129.
DOI:
NIE Xiaofeng, LI Dongyang, LIU Yuan, et al. Transformation and optimization of baghouses of two 300t/h CFB boilers[J]. Thermal power generation, 2013, 42(9): 125-129.DOI:
Transformation and optimization of baghouses of two 300t/h CFB boilers
摘要
内蒙古鄂尔多斯双欣电力公司2×300t/h循环流化床(CFB)锅炉袋式除尘器一直存在运行阻力偏高
滤袋破损率高等问题
严重影响机组带负荷能力。为此
通过试验测试和数值模拟分析
对滤袋破损原因、烟气参数、除尘器结构和流场分布等进行了全面研究
并对袋式除尘器进行了优化改造
如将原除尘器中间进气改为两侧水平直通进气
在原除尘器进口前增设4 500mm长壳体和钢支架
将原上箱体、中箱体提高3 000mm
滤袋增长至7 550mm等。改造后
烟尘排放≤30mg/m3
设备运行阻力降低700Pa
引风机电耗降低
解决了滤袋破损问题
实现了锅炉满负荷稳定运行
每年可为企业创造经济效益1 552.6万元。
Abstract
High running resistance and frequent bag broken occurred all the time on 2×300t/h circulating fluidized bed(CFB)boilers in Inner Mongolia Erdos Shuangxin power company.Therefore
experimental test and numerical simulation were conducted to systematically investigate the filter-bag broken reasons
gas parameters
dust collector structure and flow field distribution.Moreover
several measures were taken to optimize the bag dust collector
such as changing the original precipitator's intermediate gas admission into two sides horizontal direct gas admission
adding shell with length of 4 500mm and steel bracket at inlet of the original precipitator
up moving the original upper and middle boxes by 3 000mm and extending the filter bag to 7 550mm.After the transformation
the dust emission was reduced below 30 mg/m3
the equipment running resistance was decreased by 700Pa
the electricity consumption of induced draft fans was dropped
and the filter bag's broken problem was solved.The optimization realized stable operation of the boilers under full load condition