摘要
通过宏观检验、电镜观察和理论计算
对同时承受机械应力和热应力的锅炉减温器喷水管失效断口形貌进行分析
研究其断裂模式与原因。结果表明
该喷水管断裂属于于热-机械疲劳断裂
交变弯曲应力和热应力是其断裂失效的主要原因。热应力使管内壁产生浅表性热疲劳裂纹
并导致机械疲劳裂纹稳定扩展至该区时发生局部快速扩展
产生局部快速断裂区
其形貌不同于常规疲劳断口最后瞬断区。
Abstract
With macrographic examination
SEM observation and theoretical calculation
fracture fractography of a spray tube with both mechanical stress and thermal stress in a boiler desuperheater in a power plant was interpreted
and rupture mode and causes were researched.The results showed that rupture of the spray tube was due to fatigue
and further
thermal-mechanical fatigue.Alternating bending stress and thermal stress were main factors of rupture failure.Shallow surface thermal fatigue cracks inside tube were induced by thermal stress.When thermal-mechanical fatigue crack grew up steadily to the shallow surface cracks region
fast growth occurred and local fast rupture region generated which had different fractography with final rupture region of conventional fatigue fracture.