Numerical simulation on NOx emission from a 300 MW unit boiler
|更新时间:2025-09-28
|
Numerical simulation on NOx emission from a 300 MW unit boiler
Thermal Power GenerationVol. 42, Issue 6, Pages: 51-57(2013)
作者机构:
1. 华北电力科学研究院有限责任公司
2. 华北电力大学能源动力与机械工程学院
作者简介:
基金信息:
DOI:
CLC:TK229.6
Published:2013
稿件说明:
移动端阅览
TONG Jialin1, 2, ZHAO Zhenning1, et al. Numerical simulation on NOx emission from a 300 MW unit boiler[J]. Thermal power generation, 2013, 42(6): 51-57.
DOI:
TONG Jialin1, 2, ZHAO Zhenning1, et al. Numerical simulation on NOx emission from a 300 MW unit boiler[J]. Thermal power generation, 2013, 42(6): 51-57.DOI:
Numerical simulation on NOx emission from a 300 MW unit boiler
Numerical simulation on NOx emission characteristic of a 300 MW subcritical coal fired boiler was performed.The effects of such factors as excess air coefficient
over fire air ratio
coal concentration ratio of coal rich side to the lean side and the primary air speed on the furnace temperature field and NOx emission was investigated.The results showed that
with a drop in excess air coefficient and an increase in over fire air ratio
the NOx emission decreased.The higher the coal concentration ratio of coal rich side to the lean side
the lower the NOx emitted.The increasing primary air speed resulted in high NOx emission.After regulation according to the simulation results