High exhaust temperature of an HG-1900 / 25.4-HM2boiler : cause analysis and countermeasures
|更新时间:2025-09-28
|
High exhaust temperature of an HG-1900 / 25.4-HM2boiler : cause analysis and countermeasures
Thermal Power GenerationVol. 42, Issue 7, Pages: 109-114(2013)
作者机构:
1. 辽宁省电力有限公司电力科学研究院
2. 华润电力(贺州)有限公司
作者简介:
基金信息:
DOI:
CLC:TK227
Published:2013
稿件说明:
移动端阅览
SONG Dayong1, DI Wanfeng2, ZHANG Jiawei 1, et al. High exhaust temperature of an HG-1900 / 25.4-HM2boiler : cause analysis and countermeasures[J]. Thermal power generation, 2013, 42(7): 109-114.
DOI:
SONG Dayong1, DI Wanfeng2, ZHANG Jiawei 1, et al. High exhaust temperature of an HG-1900 / 25.4-HM2boiler : cause analysis and countermeasures[J]. Thermal power generation, 2013, 42(7): 109-114.DOI:
High exhaust temperature of an HG-1900 / 25.4-HM2boiler : cause analysis and countermeasures
The cause of high exhaust gas temperature of an HG-1900/25.4-HM2boiler was analyzed from design and operation aspects.The results showed that:(1)because of the increase of flue gas volume and specific heat capacity and other factors
the design value of exhaust temperature of boilers firing lignite coal was about 20℃higher than that firing bituminous coal;(2)a decrease in total heat transfer efficiency of tail heating surface caused by over small opening degree of the reheater damper
the gas temperature at air preheater inlet was higher than the design value which caused by serious fouling on the tail heating surface
drop of the air volume and theoretical air volume ratio(β″)at the air preheater outlet
and the gas temperature at air preheater inlet was higher than the design value were the main reasons for high exhaust temperature.Thus
measures such as increasing the air temperature set value at coal mill outlet
optimizing the soot blowing and enlarging opening degree of the reheater gas damper were adopted.After the improvement