Economic analysis on control mode of high-pressure valve in CC50 steam turbines with double extraction
|更新时间:2025-09-28
|
Economic analysis on control mode of high-pressure valve in CC50 steam turbines with double extraction
Thermal Power GenerationVol. 42, Issue 4, Pages: 6-8(2013)
作者机构:
中石油长岭分公司动力厂
作者简介:
基金信息:
DOI:
CLC:TK263
Published:2013
稿件说明:
移动端阅览
LI Honghua The Power Plant of Changling Branch Company in China Petrochemical Corporation. Economic analysis on control mode of high-pressure valve in CC50 steam turbines with double extraction[J]. Thermal power generation, 2013, 42(4): 6-8.
DOI:
LI Honghua The Power Plant of Changling Branch Company in China Petrochemical Corporation. Economic analysis on control mode of high-pressure valve in CC50 steam turbines with double extraction[J]. Thermal power generation, 2013, 42(4): 6-8.DOI:
Economic analysis on control mode of high-pressure valve in CC50 steam turbines with double extraction
The influence of single valve control and sequence valve control for high-pressure valve of CC50 double extraction steam turbines on such indices as the extraction parameters of each section
inner efficiency and electric energy production were studied by calculation.The results showed that
compared with the single valve control
the unit under sequence valve control had lower extraction temperature
obviously at the first to third stage extraction.The inner efficiency of the first extraction stage and the whole turbine was increased by 7.56% and 0.46%
respectively.The unit electric energy production had a growth of 0.74 MW.