Parameter optimization on low-temperature reheating organic Rankine cycle
|更新时间:2025-09-28
|
Parameter optimization on low-temperature reheating organic Rankine cycle
Thermal Power GenerationVol. 42, Issue 5, Pages: 22-29(2013)
作者机构:
华北电力大学能源动力与机械工程学院
作者简介:
基金信息:
DOI:
CLC:TK123
Published:2013
稿件说明:
移动端阅览
WANG Zhi, YU Yida, HAN Zhonghe, et al. Parameter optimization on low-temperature reheating organic Rankine cycle[J]. Thermal power generation, 2013, 42(5): 22-29.
DOI:
WANG Zhi, YU Yida, HAN Zhonghe, et al. Parameter optimization on low-temperature reheating organic Rankine cycle[J]. Thermal power generation, 2013, 42(5): 22-29.DOI:
Parameter optimization on low-temperature reheating organic Rankine cycle
By taking R601 and R245ca as the cycle working fluid
the influence of reheat pressure ratio on low-temperature reheating organic Rankine cycle(ORC) system was investigated
on the basis of the first and second law of thermodynamics.Combined with programming through MATLAB and BEFPROP
the system net work was taken as the objective function to determine the optimal reheat pressure ratio.The results showed that
with an increase in evaporation temperature
the reheat pressure ratio gradually reduced while the system net work increased;the heat efficiency rose but the exergy efficiency decreased.The increase range of system net work was higher than that of the heat efficiency and exergy efficiency.In practical application