Performance study on water drenching filler with modified small spacing in cooling towers
|更新时间:2025-09-28
|
Performance study on water drenching filler with modified small spacing in cooling towers
Thermal Power GenerationVol. 42, Issue 7, Pages: 70-73(2013)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TU991.42
Published:2013
稿件说明:
移动端阅览
JIA Mingxiao, HU Sanji, CHEN Yuling Xi'an Thermal Power Research Institute Co.. Performance study on water drenching filler with modified small spacing in cooling towers[J]. Thermal power generation, 2013, 42(7): 70-73.
DOI:
JIA Mingxiao, HU Sanji, CHEN Yuling Xi'an Thermal Power Research Institute Co.. Performance study on water drenching filler with modified small spacing in cooling towers[J]. Thermal power generation, 2013, 42(7): 70-73.DOI:
Performance study on water drenching filler with modified small spacing in cooling towers
Experimental study on performance of a modified small spacing"V" wave water drenching filler with assembling height of 1mand plate spacing of 22mm was conducted.The least square method was applied to put forward the thermal performance and resistance characteristic equations.Moreover
performance of the above filter and the conventional water drenching filler with plate spacing of 30mm was compared.It indicated that
within the range of common air to water ratio for countercurrent natural draft cooling towers
the thermal performance of the modified water drenching filter was enhanced by 21%to 28%
compared with the water drenching filter with conventional plate spacing
and its ventilation resistance was 83%to 99% of that of the latter one.Furthermore
the modified"V" wave water drenching filter was applied in a natural draft cooling tower with spraying area of 5 000m2.Calculation showed that the water temperature at outlet of the tower was about 1℃lower than that of the tower using"V"wave water drenching filter with conventional plate spacing
ENERGY-SAVING RETROFIT OF NATURAL DRAFT COOLING TOWER
CORRELATION BETWEEN TEST COEFFICIENTS OF INDUSTRIAL COOLING TOWER AND SIMULATED TESTING TOWER
CAUSE ANALYSIS OF LOW VACUUM FOR UNIT NO.1 IN LAICHENG POWER PLANT AND REMEDY THEREOF
MEASUREMENT AND CALCULATION METHOD FOR THERMAL PERFORMANCE TEST OF ULTRA-SUPERCRITICAL UNIT WITH STEAM TURBINE EQUIPPED WITH DOUBLE-ROW HIGH-PRESSURE HEATERS
GX TYPE CENTRIFUGAL HIGH-EFFICIENT SPRAYING EQUIPMENT FOR COOLING TOWER EFFICIENCY ENHANCEMENT
Related Author
CHEN Yu-ling et al
HU San-ji
CHEN Yuling
WANG Cheng-liang Laicheng Power Plant
AN Hong-xinXi'an Thermal Power Insititute Co Ltd
ZHONG Ping
YAO Xiao-lin
ZHU Li-tong
Related Institution
Xi'an Thermal Power Research Institute Co.,Ltd.
Laicheng Power Plant
College of Energy, Power and Mechanical Engineering, North China Electric Power University
College of Mechanical Engineering, Hebei University of Technology