Experimental study on heat transfer performance of a new type high temperature heat pipe with combined wick
|更新时间:2025-09-28
|
Experimental study on heat transfer performance of a new type high temperature heat pipe with combined wick
Thermal Power GenerationVol. 42, Issue 5, Pages: 59-63(2013)
作者机构:
1. 国核电力规划设计研究院
2. 南京工业大学能源学院
作者简介:
基金信息:
DOI:
CLC:TK172.4
Published:2013
稿件说明:
移动端阅览
BAI Tong1, ZHANG Hong2, XU Hui2 1.State Nuclear Electric Power Planning Design & Research Institute. Experimental study on heat transfer performance of a new type high temperature heat pipe with combined wick[J]. Thermal power generation, 2013, 42(5): 59-63.
DOI:
BAI Tong1, ZHANG Hong2, XU Hui2 1.State Nuclear Electric Power Planning Design & Research Institute. Experimental study on heat transfer performance of a new type high temperature heat pipe with combined wick[J]. Thermal power generation, 2013, 42(5): 59-63.DOI:
Experimental study on heat transfer performance of a new type high temperature heat pipe with combined wick
摘要
设计了1种新型组合式热管吸液芯
并搭建了热管性能测试系统
以研究工作倾角及输入交变热流对该型吸液芯高温热管传热性能的影响。结果表明
与普通三角沟槽吸液芯的高温热管相比
组合式吸液芯高温热管可在0°、25°和45°的倾角下正常工作
其管壁温度的均温性较好
当量导热系数随输入交变热流的增加而增加较大
而三角沟槽由于无法提供足够的毛细抽力
限制了高温热管在大倾角工作条件下的传热性能。
Abstract
To investigate the influence of working inclination angle and alternating heat flux on the heat transfer performance of high temperature heat pipe
a new combined wick was designed and the heat pipe performance test system was constructed.The experimental results showed that
compared with the high temperature heat pipe with regular triangle grooved wick
the one with the combined wick can work normally at inclination angle of 0°
25° and 45°.Its tube wall temperature was uniform.The effective thermal conductivity increased a lot with the input alternating heat flux.However
the triangular groove limited the heat transfer performance of the high temperature heat pipe working with large inclination angle