Energy consumption of 1 000 MW units:diagnosis and analysis
|更新时间:2025-09-28
|
Energy consumption of 1 000 MW units:diagnosis and analysis
Thermal Power GenerationVol. 42, Issue 5, Pages: 19-21(2013)
作者机构:
中国神华国华电力分公司
作者简介:
基金信息:
DOI:
CLC:TM621
Published:2013
稿件说明:
移动端阅览
SUN Zhichun Guohua Electric Power Branch. Energy consumption of 1 000 MW units:diagnosis and analysis[J]. Thermal power generation, 2013, 42(5): 19-21.
DOI:
SUN Zhichun Guohua Electric Power Branch. Energy consumption of 1 000 MW units:diagnosis and analysis[J]. Thermal power generation, 2013, 42(5): 19-21.DOI:
Energy consumption of 1 000 MW units:diagnosis and analysis
The equipments and systems and the main operation economic indices of four ultra supercritical 1000 MW units in Ninghai and Suizhong Power Plants of Shenhua Guohua Electric Power Company were analyzed to investigate the major factors affecting the unit operation economy and calculate the influence quality.Thus
the corresponding energy saving measures were put forward
and the expecting effects were quantatively calculated.For the No.3 and No.4 units in Ninghai Power Plant
the coal consumption for power generation can both be reduced by 4.0 g/(kW·h);the auxiliary power consumption rate can both be dropped by 0.47%;the converted coal consumption for power supply can both be decreased by 5.6 g/(kW·h).For the No.3 and No.4 units in Suizhong Power Plant
the coal consumption for power generation can be reduced by 2.8 g/(kW·h) and 2.6 g/(kW·h)