Key technologies of double reheat &heat regeneration systems for large scale steam turbines
The structure of the double reheat and heat regeneration system was presented.Key technologies including the number of regeneration stage
the external steam cooler
HARP
double reheat and the new MC system were discussed.Taking an ultra supercritical 800MW unit as the example
comparison between and among the unit applying the double reheat heat regeneration system and that combined with MC system and that applying single reheat heat regeneration system was performed.The results showed that
under the second reheat condition
the main steam pressure increased by 1.4MPa
while the main steam temperature dropped by 5℃
the unit heat consumption decreased by about 226kJ/(kW·h)
and the heat efficiency rose by 1.4%.Compared with the single reheat system
for the MC system
the main steam pressure increased by3.8MPa
while the main steam temperature dropped by 5℃
the unit heat consumption decreased by about 235kJ/(kW·h)
and the heat efficiency rose by about 1.45%.The system efficiency of the MC system increased little than that of the typical double reheat and heat regeneration system.However
the technical advantage of the MC system relies on further improvement of the high back pressure turbine.
STUDY ON LOAD UNDER ECONOMIC OPERATION OF ULTRA-SUPERCRITICAL UNITS
NON-DESTUCTIVE INSPECTION OF AUTOMATIC WELDING DEFECTS FOR BOILER PIPES WITH SMALL DIAMETER AND LARGE WALL-THICKNESS IN ULTRA-SUPERCRITICAL UNITS
CAUSE ANALYSIS OF REAR PLATEN SUPERHEATER LEAKAGE FOR BOILER OF ULTRA-SUPERCRITICAL UNIT AND REMEDIAL MEASURES THEREOF
STRENGTH ANALYSIS OF HOT EXTRUDED TEE-TYPE UNEQUAL-DIAMETER THREE-WAY JOINT FOR MAIN STEAM PIPELINE OF ULTRA-SUPERCRITICAL UNIT
MEASUREMENT AND CALCULATION METHOD FOR THERMAL PERFORMANCE TEST OF ULTRA-SUPERCRITICAL UNIT WITH STEAM TURBINE EQUIPPED WITH DOUBLE-ROW HIGH-PRESSURE HEATERS
Related Author
LEI Zhao-tuanXi’an Thermal Power Research Institute Co Ltd