Startup method for fluidized bed boiler with high-powe r up-bed heavy oil burner
|更新时间:2025-09-28
|
Startup method for fluidized bed boiler with high-powe r up-bed heavy oil burner
Thermal Power GenerationVol. 42, Issue 11, Pages: 159-163(2013)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK227;TK223.23
Published:2013
稿件说明:
移动端阅览
DANG Xiaojian, WU Shougui, LIU Aijun, et al. Startup method for fluidized bed boiler with high-powe r up-bed heavy oil burner[J]. Thermal power generation, 2013, 42(11): 159-163.
DOI:
DANG Xiaojian, WU Shougui, LIU Aijun, et al. Startup method for fluidized bed boiler with high-powe r up-bed heavy oil burner[J]. Thermal power generation, 2013, 42(11): 159-163.DOI:
Startup method for fluidized bed boiler with high-powe r up-bed heavy oil burner
摘要
目前国内循环流化床(CFB)锅炉大部分采用床上、床下燃烧器联合启动方式
仅配置床上高功率重油燃烧器的CFB锅炉由于参数控制难度大
启动过程极易结焦。对此
通过对国外某电厂锅炉重油启动燃烧器启动过程的分析
提出了提高给水温度、减小总风量、控制主蒸汽压力等启动方法
以及对启动过程中一、二次风、床压及燃烧器、锅炉升温速率、投煤参数等的控制要求
可为今后同类型CFB锅炉启动提供借鉴。
Abstract
At present
most of the domestic circulating fluidized bed boilers(CFB)start up in the mode of up-bed and down-bed burner combining start-up.Because of the difficulty in controlling the parameters
the CFB boilers equipped with only high-power up-bed heavy oil burner easily slagged.Thus
the start-up process of a foreign boiler with heavy oil burner was analyzed
and the start-up method that increasing the feedwater temperature
decreasing the total air volume and controlling the main steam pressure were put forward.Furthermore
requirements for the primary air and secondary air
bed pressure
heating rate of the burner and coal input parameters during the boiler start-up process were also presented.