Reason analysis for filter bag damage in a coal-fired power plant
|更新时间:2025-09-28
|
Reason analysis for filter bag damage in a coal-fired power plant
Thermal Power GenerationVol. 43, Issue 1, Pages: 110-114(2014)
作者机构:
河南省电力公司电力科学研究院
作者简介:
基金信息:
DOI:
CLC:X701.2
Published:2014
稿件说明:
移动端阅览
LI Dongmei, TIAN Yujia, GUO Yang, et al. Reason analysis for filter bag damage in a coal-fired power plant[J]. Thermal power generation, 2014, 43(1): 110-114.
DOI:
LI Dongmei, TIAN Yujia, GUO Yang, et al. Reason analysis for filter bag damage in a coal-fired power plant[J]. Thermal power generation, 2014, 43(1): 110-114.DOI:
Reason analysis for filter bag damage in a coal-fired power plant
Particulate matter emissions beyond the standard occurred in a coal-fired power plant
which is caused by damage of some filter bags in bag house.The unit operation parameters
the bag house structure and the apparent damage situation of the filter bags were analyzed.A series of tests such as the residual tensile strength/elongation test
the Fourier transform infrared spectroscopy(FTIR)analysis and differential scanning calorimetry(DSC)were performed to conduct comprehensive analysis on reason of damage at filter bag mouth and bottom
bag cage bottom cap
and outer layer of the filter bottom.Finally
several countermeasures were put forward
such as detecting and accepting the new filter bags according to corresponding standards
random inspecting the running bags regularly
ensuring the position deviation between the centerline of stream sprayed from the nozzles and the bag center be within 2mm
ensuring the bag cage be installed vertically
conducting anti-corrosion treatment or changing the bag cage timely
checking the system air leakage and repairing it timely.