Simple calculation of SO2 concentration in flue gas from a CFB boiler and the desulfurization efficiency
|更新时间:2025-09-28
|
Simple calculation of SO2 concentration in flue gas from a CFB boiler and the desulfurization efficiency
Thermal Power GenerationVol. 43, Issue 2, Pages: 58-60(2014)
作者机构:
华能清洁能源技术研究院有限公司
作者简介:
基金信息:
DOI:
CLC:X701.3
Published:2014
稿件说明:
移动端阅览
HUANG Zhong. Simple calculation of SO2 concentration in flue gas from a CFB boiler and the desulfurization efficiency[J]. Thermal power generation, 2014, 43(2): 58-60.
DOI:
HUANG Zhong. Simple calculation of SO2 concentration in flue gas from a CFB boiler and the desulfurization efficiency[J]. Thermal power generation, 2014, 43(2): 58-60.DOI:
Simple calculation of SO2 concentration in flue gas from a CFB boiler and the desulfurization efficiency
SO2 concentration in flue gas is an important environmental index for CFB boilers
and is also the main basis for desulfurization efficiency calculation.A simple calculation method for SO2 concentration was proposed
which applying the equation C0SO2=55 922×St
ar/Qnet
ar.This method doesn't need the ultimate analysis results
it can obtain the SO2 concentration and desulphurization only via the low calorific value(received basis)and total sulfur content of the fuel.The desulphurization efficiency of CFB boilers includes the calculated desulphurization efficiency and the actual desulphurization efficiency.Generally
the actual desulphurization efficiency is lower than the calculated one.