Sealing system optimization for air preheater in a 600 MW boiler
|更新时间:2025-09-28
|
Sealing system optimization for air preheater in a 600 MW boiler
Thermal Power GenerationVol. 42, Issue 10, Pages: 127-130(2013)
作者机构:
南阳鸭河口发电有限责任公司
作者简介:
基金信息:
DOI:
CLC:TK223.34
Published:2013
稿件说明:
移动端阅览
LIU Yongfeng, YU Dezhong, ZHANG Zhongzhou, et al. Sealing system optimization for air preheater in a 600 MW boiler[J]. Thermal power generation, 2013, 42(10): 127-130.
DOI:
LIU Yongfeng, YU Dezhong, ZHANG Zhongzhou, et al. Sealing system optimization for air preheater in a 600 MW boiler[J]. Thermal power generation, 2013, 42(10): 127-130.DOI:
Sealing system optimization for air preheater in a 600 MW boiler
Sector plate automatic control system fault and large air leakage rate occurred on four LAP13494/2200 type rotary air preheaters equipped on phaseⅡ 2×600 MW units in Nanyang Yahekou Power Plant.The sealing gap device existing in high temperature zone for long time and the sector plate regulation device equipped on air preheater is out of control were considered as the major reasons.By applying the three sealing technology
Joe drag seal technology
and new type of radial seal structure
and combining with the automatic control system
the sealing clearance system was optimized.The tests after the optimization showed that
the air leakage rate decreased from 10% to below 5%
which satisfied the design requirement.The automatic control quality and safe economy of the system was greatly improved.