Application of the PASS system in preventing slagging in high temperature heating surface of boilers
|更新时间:2025-09-28
|
Application of the PASS system in preventing slagging in high temperature heating surface of boilers
Thermal Power GenerationVol. 42, Issue 10, Pages: 131-133(2013)
作者机构:
华能海门电厂
作者简介:
基金信息:
DOI:
CLC:TK223.32
Published:2013
稿件说明:
移动端阅览
ZHU DeYong, ZENG Biqun, YANG Bo. Application of the PASS system in preventing slagging in high temperature heating surface of boilers[J]. Thermal power generation, 2013, 42(10): 131-133.
DOI:
ZHU DeYong, ZENG Biqun, YANG Bo. Application of the PASS system in preventing slagging in high temperature heating surface of boilers[J]. Thermal power generation, 2013, 42(10): 131-133.DOI:
Application of the PASS system in preventing slagging in high temperature heating surface of boilers
The factors affecting the slagging on tubes of superheaters and reheaters were analyzed.Reducing the heat absorption deviation between each panel was pointed out as the key points to prevent slagging.Improving the uniformity of temperature and speed of flue gas in boiler width direction was the effective way to eliminate the heat deviation of superheaters and reheaters.The high temperature panel safeguard supervisory system(PSSS)was applied to investigate the temperature field variation and slagging on tube panel of superheater and reheater in boiler of ultra supercritical 1036MW unit in Huaneng Haimen Power Plant phase I.After several measures were taken
such as optimizing the aerodynamic field in furnace
preventing the flame swepting and adhereing the water wall
effectively controlling the formation of reducing gas in furnace
decreasing the flue gas temperature
and conducting soot blowing
the ash deposition and slagging on high temperature reheater was eliminated.