Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method
|更新时间:2025-09-28
|
Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method
Thermal Power GenerationVol. 42, Issue 12, Pages: 132-134(2013)
作者机构:
西安热工研究院有限公司
作者简介:
基金信息:
DOI:
CLC:TK222
Published:2013
稿件说明:
移动端阅览
WU Shenglai, ZHAO Yongjian, GUO Rui. Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method[J]. Thermal power generation, 2013, 42(12): 132-134.
DOI:
WU Shenglai, ZHAO Yongjian, GUO Rui. Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method[J]. Thermal power generation, 2013, 42(12): 132-134.DOI:
Discussion on correction calculation of pressure loss in steam and water system by the ASME PTC4-2008 method
On the basis of tracing the deviation of the Bernoulli equations
the ASME PTC4-2008 correction calculation method for pressure loss in boiler steam and water system was considered improper.It proposed that fluid in the superheater
reheater and economizer should follow the law of energy balance.Suggestions that it is better not regard the pressure drop in superheater
reheater and economizer as the performance evaluation index were put forward.