Least square support vector machine based economic evaluation method for heaters in steam turbines
|更新时间:2025-09-28
|
Least square support vector machine based economic evaluation method for heaters in steam turbines
Thermal Power GenerationVol. 43, Issue 2, Pages: 9-11(2014)
作者机构:
东北电力大学能源与动力工程学院
作者简介:
基金信息:
DOI:
CLC:TK267
Published:2014
稿件说明:
移动端阅览
LI Yong, LIU Zhe. Least square support vector machine based economic evaluation method for heaters in steam turbines[J]. Thermal power generation, 2014, 43(2): 9-11.
DOI:
LI Yong, LIU Zhe. Least square support vector machine based economic evaluation method for heaters in steam turbines[J]. Thermal power generation, 2014, 43(2): 9-11.DOI:
Least square support vector machine based economic evaluation method for heaters in steam turbines
The least squares support vector machine(LS-SVM)and RBF kernel function model were applied to calculate the target value of terminal temperature difference of low-pressure heaters
and performance evaluation of the heaters was conducted according to the difference between the target value and measured value.Taking normal operation state of the No.6low-pressure heater in a 300MW unit turbine as the example
the feasibility of using the LS-SVM model to calculate the target value of terminal temperature difference of the low-pressure heater was verified.Finally
economical efficiency of the heater at fault state was evaluated by the LS-SVM model.The results showed that
the mean square deviations between the measured and target value of upper and bottom terminal temperature difference of the heater were 0.536 3℃and 5.055 3℃
respectively
both far larger than that at the normal operation state(0.005 3 ℃ and 0.007 8 ℃).This indicated fault has happened on the heater.The inspection validated that
leakage occurred on bypass door between the No.6and No.7low-pressure heater
and water level in the No.6lowpressure heater was too low.Therefore
the LS-SVM model was preferred to evaluate the economic efficiency of the low-pressure heater's performance
and it also can discover the heater fault at an early time.