Air leakage control and energy-saving application of air preheater in thermal power plants
|更新时间:2025-09-28
|
Air leakage control and energy-saving application of air preheater in thermal power plants
Thermal Power GenerationVol. 43, Issue 6, Pages: 132-135(2014)
作者机构:
1. 清华大学热能工程系
2. 北京能源投资(集团)有限公司
3. 东南大学热能动力实验室
作者简介:
基金信息:
DOI:
CLC:TK223.34
Published:2014
稿件说明:
移动端阅览
JIN Shengxiang, He Qishan, LI Qianyu, et al. Air leakage control and energy-saving application of air preheater in thermal power plants[J]. Thermal power generation, 2014, 43(6): 132-135.
DOI:
JIN Shengxiang, He Qishan, LI Qianyu, et al. Air leakage control and energy-saving application of air preheater in thermal power plants[J]. Thermal power generation, 2014, 43(6): 132-135.DOI:
Air leakage control and energy-saving application of air preheater in thermal power plants
摘要
运用柔性接触式密封技术对某火电厂烟风系统三分仓回转式空气预热器(空预器)进行漏风治理和密封改造
与常规漏风治理措施相比进一步降低了空预器漏风率
在机组高负荷下空预器平均漏风率由8.350%降至4.045%
同时使供电煤耗下降约0.71g/(kW·h)
引风机和一次风机电机功率平均下降12.2%和18.85%
引风机节电率达到12.15%
一次风机节电率达到19.51%
按0.373元/(kW·h)计算
空预器漏风改造每年能节约电费227.5万元
经济效益显著。
Abstract
The flexible contact seal technology was employed to conduct air leakage control and seal transformation for tri-sectional regenerative air pre-heater in a thermal power plant.Compared with the conventional air leakage control measures
application of this technology further decreased air leakage rate of the air preheater
the average value under high unit load condition dropped from 8.35% to 4.405%.Moreover
the coal consumption rate for power supply reduced by about 0.71g/(kW·h)
the mean electric power of the induced draft fan and primary air fan decreased to 12.2% and 18.85%
respectively.Furthermore
the electric saving rate of induced draft fan reached 12.15%
that of the primary air fan went to 19.51%.Supposing the electricity price is of 0.373yuan/(kW·h)
by air leakage retrofit
the air preheater can save electricity by2.275×106 yuan yearly.