Comparative study on blended coal combustion and performance test for two domestic 300MW CFB boilers
Taking two domestic 300MW CFB boilers in a power plant as the research object
the effect of blended coal combustion
Ca/S mole ratio and load variation on desulfurization efficiency and emission characteristics of SO2 and NOx were experimentally investigated.The results show that
during the blended coal combustion
the boiler efficiency fell with the coal's heat value;the desulfurization efficiency increased with the Ca/S mile ratio
but will change little when the Ca/S mole ratio excessed 3.0;with the Ca/S mole ratio increased
the SO2 emission dropped
while the NOx emission rose;the boiler efficiency reached the highest when the unit was at 80% BMCR load;the emission of both SO2 and NOx decreased with the unit load.