Improved MED mode based numerical simulation on wall erosion in CFB boilers
|更新时间:2025-09-28
|
Improved MED mode based numerical simulation on wall erosion in CFB boilers
Thermal Power GenerationVol. 43, Issue 7, Pages: 66-71(2014)
作者机构:
西安交通大学动力工程多相流国家重点实验室
作者简介:
基金信息:
DOI:
CLC:TK229.66
Published:2014
稿件说明:
移动端阅览
GENG Yongming, LI Yongchao, WU Xiaoming, et al. Improved MED mode based numerical simulation on wall erosion in CFB boilers[J]. Thermal power generation, 2014, 43(7): 66-71.
DOI:
GENG Yongming, LI Yongchao, WU Xiaoming, et al. Improved MED mode based numerical simulation on wall erosion in CFB boilers[J]. Thermal power generation, 2014, 43(7): 66-71.DOI:
Improved MED mode based numerical simulation on wall erosion in CFB boilers
The effects of operation conditions and particle properties on wall erosion rate in CFB boilers were investigated by using two-fluid model approach by the commercial software Fluent 6.3.26.The wall erosion rate was calculated by the improved monolayer energy dissipation(MED)erosion model which was modified by the kinetic theory of granular flow(KTGF).The simulated results were compared with the available experimental data and numerical findings in the literatures for model validation.Then the effects of operation parameters such as gas superficial velocity
total bed inventory
particle diameter and density on the wall erosion rate were numerically studied.The results indicate that:the wall erosion rate increased with the fluidizing velocity and bed inventory;under the same operation conditions
smaller and lighter particles led to a higher erosion rate and more spacious erosion scope.